Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 




 
MRI Forum
'Echo'
SEARCH FORUM FOR   
 
Result: Searchterm 'Echo' found in 43 messages
Result Pages: 1 2 3 4 5 [6] 7 8 9 
More Results: Database  (305)  News Service  (7)  Resources  (10)  
Forum Overview
 bottom
Mike Benji

Tue. 13 Jan.09,
01:17

[Reply (2 of 7) to:
'Which MRI machine to buy?'
started by: 'Mike Benji'
on Fri. 12 Dec.08]


 
  Category: 
Devices, Scanner, Machines

 
Which MRI machine to buy?
Sandra,

Yes, this is our first MRI machine, we are currently a broker. Through more research I agree with you and have decided on finding a GE Echospeed Plus, they can be found for around 250k and seem to offer great "bang for the buck"

Your thoughts?
 View the whole thread
Richard Powell

Wed. 26 Nov.08,
14:58

[Start of:
'Neuro vascular array does not perform DWI'
0 Reply]


 
  Category: 
Equipment

 
Neuro vascular array does not perform DWI
We recently had an software upgrade to our GE 1.5T Echospeed. The diffusion weighted imaging stopped working when using the neuro vascular array. Has any one else experienced this problem? What was done to correct the problem?
Reply to this thread
(login or register first)
Maricella Sauceda

Thu. 16 Oct.08,
22:33

[Start of:
'Translation of MRI Result - Help'
0 Reply]


 
  Category: 
Applications and Examinations

 
Translation of MRI Result - Help
Okay... So below is what the MRI breakdown tells me, can someone tell me if I should definitely be worried... I think it says I have brain lessions associated to sinus problems, but then they said it might be a sign of MS? HELP... Any additional clarity will be greatly appreciated...

Technique: Sequences spin - echo-enhanced in T1, T2 protons and density, flair at the axial, sagittal and coronal, 5 mm thick.

Report:
Small punctate signals focal hypo-intense in T1 and hypertensive in the other sequences and without apparent mass effect in the lobar white matter and subcortical frontal, bilateral parietal subcortical and peri-ventricular the atriums of both lateral ventricles.
Others are not displayed disturbances of encephalic parenchyma or blood collections or intra extraxiales. The medulla oblongata, pons and the cerebral peduncles with normal morphology and signal. Tanks of the base, the subarachnoid space and the cortical ventricular system above and infratentorial not dilated, without compression or movement.
Thickening of the lining which is the frontal sinuses, ceidillas etmoidales and maxillary sinuses, in the latter left with the presence of liquid level.

Comments
Many small pictures that compromise the lobar white matter and subcortical frontoparietal and peri-ventricular atrial bilateral and that although might be nonspecific, it is not possible to rule out entirely demyelinating etiology, so it must be correlated with the clinic's patient, findings of physical examination and clinical-. A new study of control in timely fashion or according to clinical course can be useful.
Pan-chronic sinusitis with signs of acute in the left maxillary sinus.
Reply to this thread
(login or register first)
Hugo Robalo

Thu. 3 Apr.08,
16:22

[Reply (2 of 4) to:
'MRI Bandwidth and turbo factor relation ?'
started by: 'young bong we'
on Thu. 20 Mar.08]


 
  Category: 
Basics and Physics

 
MRI Bandwidth and turbo factor relation ?
A higher BW will increase the noise, minimum FoV, slices per TR and will decrease the minimum TE, SNR and echo spacing.
 View the whole thread
martin chavez

Thu. 31 Jan.08,
00:59

[Reply (1 of 2) to:
'gre trauma ax'
started by: 'diana navarro'
on Tue. 29 Jan.08]


 
  Category: 
Applications and Examinations

 
gre trauma ax
this is a t2* or gradient echo and we use this for all head trauma pt's and to look for old blood in the brain.
gre trauma ax comes from a ge protocol and thats
what ge named that sequence.
 View the whole thread

Result Pages : 1 2 3 4 5 [6] 7 8 9 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 September 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]