Mosta Mosta
Tue. 3 Mar.09, 19:45
[Reply (2 of 3) to: 'LOOKING FOR A JOB' started by: 'Arnaldo Escalona' on Mon. 29 Dec.08]
Category:
Jobs |
LOOKING FOR A JOB |
Hello,
we are looking for MRI Technologists with good experiance at King Fahad Specialist Hospital-Dammam, Saudi Arabia. please let me know if you are interested to work overseas.
our medical imaging departmnet is equiped with two MRI scanners,
1- 1.5T GE HDxT
2- 3T Siemens Trio Tim (under construction)
This invitation is open for all.
good luck
Mosta
|
| View the whole thread | | |
angel garcia
Tue. 24 Feb.09, 23:06
[Reply (3 of 4) to: 'Mechanical Ventilator outside of Scan room' started by: 'Dan Barrieau' on Wed. 20 Jun.07]
Category:
Site Planning and Specifications |
Mechanical Ventilator outside of Scan room |
Should a thermostat be inside a MRI room to measure temp.And is a MRI room a positive pressured room??I am a mechanical service tech by the way.
|
| View the whole thread | | |
James McCleery
Tue. 17 Feb.09, 18:39
[Reply (1 of 2) to: 'ASTM labeling guidlines for all portable devices' started by: 'Michelle Brantman' on Wed. 14 Jan.09]
Category:
Safety |
ASTM labeling guidlines for all portable devices |
The rule in our dept is every object with the potential of entering the MRI enviroment be labeled as safe or unsafe. The standard rule is known through out the hospital is if it is not labeled to ASK the MRI technologist on duty BEFORE bringing it into the MRI enviroment. No one person or object gets brought in without prior screening.
Old rule if you don't know: DON'T ASSUME! ASK!
|
| View the whole thread | | |
Michelle Brantman
Wed. 14 Jan.09, 17:27
[Start of: 'ASTM labeling guidlines for all portable devices' 1 Reply]
Category:
Safety |
ASTM labeling guidlines for all portable devices |
Hello All,
I am currently working though some safety issues we are have having at the hospital where I oversee MRI. It is the wish of the radiologist per the ASTM standard supported by the AJR (ASTM F2503)that "items that may be brought into the MR environment be permanently marked to indicate the MR invironment to which a specific item may safely be exposed" Our radiologist want every IV pole, pump, respiratory device - anything that might end up near the MR - be labeled. I am wondering is anyone else doing the same thing?
|
| View the whole thread | Reply to this thread (login or register first) | |
Sandra Wilson
Tue. 13 Jan.09, 17:41
[Reply (3 of 7) to: 'Which MRI machine to buy?' started by: 'Mike Benji' on Fri. 12 Dec.08]
Category:
Devices, Scanner, Machines |
Which MRI machine to buy? |
I think that is a smart choice - but are you talking about a mobile MRI or just the system? A mobile would typically be more than 250k while just the system for a fixed MRI would be less.
|