Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 




 
MRI Forum
'sequence'
SEARCH FORUM FOR   
 
Result: Searchterm 'sequence' found in 106 messages
Result Pages: 1 2 3 4 [5] 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 
More Results: Database  (378)  News Service  (28)  Resources  (10)  
Forum Overview
 bottom
CLAUDIO RIBERTI

Tue. 30 Jan.18,
13:13

[Start of:
'Siemens Skyra 3 T'
0 Reply]


 
  Category: 
Artifacts

 
Siemens Skyra 3 T
In MR cardio exams I perform a sequence called trufi-frequencyScout-multi.

This sequence provides several images (from a same slice) each one with a specific frequency.
After this, we choose the better image and use its frequency value as an entry in the cine subsequent sequences.

The question is: Where do I find the place to insert this Value in the Cine sequence?
I travelled all the cine sequence away and could not find.
Anyone can help?

Thanks a lot.
Reply to this thread
(login or register first)
Matt H

Fri. 27 Oct.17,
13:23

[Start of:
'When to shim?'
1 Reply]


 
  Category: 
General

 
When to shim?
On what sequences should a shim volume be added? (GE scanner)
 View the whole threadReply to this thread
(login or register first)
Arnold Somereville

Sun. 23 Apr.17,
18:06

[Start of:
'GE 8 channel Body Coil Artifact'
2 Replies]


 
  Category: 
Artifacts

 
GE 8 channel Body Coil Artifact
Have a GE 1.5T HDxt. Problem: experiencing symmetric artifacts in abdominal images. Artifact seen in most anterior images: Some are rectangular in appearance, another reminds me of a plastic knife. All patients are changed in gowns/pants prior to entry into MRI suite. The body coil in question has been changed 3 times but the artifact remains. I suspect this is a hardware reconstruction issue, however, the engineer thinks it is operator error. I have run this sequence with and without options. This is an SSFSE, breath hold sequence. Has anyone encountered this issue?
 
 
MRI Abdomen 8 channel body coil


 View the whole threadReply to this thread
(login or register first)
Reader Mail

Fri. 30 Dec.16,
07:16

[Start of:
'Second contrast dosage on COW MRA'
0 Reply]


 
  Category: 
Applications and Examinations

 
Second contrast dosage on COW MRA
Did anyone know how much Gadovist should I inject after first time COW MRA is failed on 1.5T Philips TOF sequence.

First time dosage is 0.15ml/kg

(Patient with normal kidney function eGFR>60)
Reply to this thread
(login or register first)
Desiree Dupuy

Sat. 3 Dec.16,
22:14

[Reply (2 of 3) to:
'Muscle shading in 3T Images'
started by: 'Travis Conley'
on Thu. 21 Oct.10]


 
  Category: 
Applications and Examinations

 
Muscle shading in 3T Images
Try running a B1 Map followed by Calibration. Set RF Drive mode to Optimized. This is supposed to optimize for your Patient. Supposed to reduce dielectric effect/shading for Lumbar and Abdomen.
You can find under GE Additional Abdomen Sequences.

Or you can run Ideal with Dixon technique. Turn on IN phase will give you T1 FS & IN Phase is you plane T1. I believe this takes care of the artifact.
 View the whole thread

Result Pages : 1 2 3 4 [5] 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 5 October 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]