Sinerem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Sinerem® is the brand name (same as Combidex®) for an ultrasmall superparamagnetic iron oxide (USPIO) to detect metastatic disease in lymph nodes. Metastatic nodes show less uptake of this MRI contrast agent, which results in less signal decrease and allows the differentiation of normal lymph nodes from normal-sized, metastatic nodes.
Lymph node imaging with Sinerem® is performed 24 to 36 hours after slow infusion. Normal lymph nodes turn black post contrast, namely on T2* weighted images. Metastatic lymph nodes remain unchanged in signal intensity.
Indication and Diseases: Cancer, Imaging for diagnosis, Lymphatic disorders.
See Ferumoxtran, and Classifications, Characteristics, etc.

Guerbet decided in 2007 to withdraw its Marketing Authorisation Application (MAA) for Sinerem.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxtran, USPIO, AMI-227
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
r1=25, r2=160, B0=0.47T, r1=23.3, r2=48.9, B0=0.47T
PHARMACOKINETIC
Vascular, lymph v. hepatocyte (AG-USPIO)
CONCENTRATION
DOSAGE
2.6 mg Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
MR angiography vascular, staging of RES-directed liver diseases, lymph nodes
DEVELOPMENT STAGE
-
DISTRIBUTOR
PRESENTATION
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer
 
Further Reading:
  Basics:
The demise of Combidex - Sinerem
Wednesday, 24 March 2010   by www.wellsphere.com    
  News & More:
Ultrasmall Superparamagnetic Particles of Iron Oxide-enhanced in vivo MRI of human atherosclerotic plaques.(.pdf)
MRI Resources 
Online Books - Process Analysis - Stent - Shielding - General - Colonography
 
Artirem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Artirem®, the arthrography-specific contrast agent for MRI is a dilute form of Dotarem® with a less concentration of Gd (1:200). Artirem® has to be injected directly into the joints for better visualization and delimitation, of the ligament and tendon structures in particular.
Drug Information and Specification
NAME OF COMPOUND
DEVELOPER
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.4, r2=4.8, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
CONCENTRATION
0,0025 mmol/ml
PREPARATION
Finished product
INDICATION
Arthrography
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Pre-filled syringes of 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
for sale
France, Switzerland
Artirem®
for sale
Australia
for sale
spacer

• View the DATABASE results for 'Artirem®' (4).Open this link in a new window

 
Further Reading:
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MRI Resources 
Education - Cardiovascular Imaging - MRI Physics - PACS - Supplies - Used and Refurbished MRI Equipment
 
B1Forum -
related threads
 
[B1] A conventional symbol for the radio frequency field strength (another symbol historically used, is H1). In MRI, B1 labels the field produced by the radio frequency coil.
The B1 field is often conceived of two vectors rotating in opposite directions, usually in a plane transverse to B0. At the Larmor frequency, the vector rotating in the same direction as the precessing spins will interact strongly with the spins.
spacer

• View the DATABASE results for 'B1' (1346).Open this link in a new window

 
Further Reading:
  News & More:
Implementation of Dual-Source RF Excitation in 3 T MR-Scanners Allows for Nearly Identical ADC Values Compared to 1.5 T MR Scanners in the Abdomen
Wednesday, 29 February 2012   by www.plosone.org    
Turbo-FLASH Based Arterial Spin Labeled Perfusion MRI at 7 T
Thursday, 20 June 2013   by www.plosone.org    
Mapping of low flip angles in magnetic resonance(.pdf)
Saturday, 1 January 2011   by www.hal.inserm.fr    
Searchterm 'B0' was also found in the following services: 
spacer
News  (1)  Forum  (4)  
 
Clariscan™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
An iron-based contrast agent with large molecular size, which prevents diffusion into body tissues and will be developed for MR imaging of the liver (taken up by macrophages), tumor microvasculature and microvessel permeability. The blood half live of the particles with 11-20 nm diameter is 3-4 hours.
At this time the development of Clariscan™ is discontinued.

See also NC100150 Injection and Ultrasmall Superparamagnetic Iron Oxide.
Drug Information and Specification
NAME OF COMPOUND
Feruglose, PEG-feron, USPIO, NC100150
DEVELOPER
CENTRAL MOIETY
Fe
CONTRAST EFFECT
T2, Predominantly negative enhancement
R1=20, R2=35, B0=0.5T
PHARMACOKINETIC
Intravascular
CONCENTRATION
29.8 mg Fe/mL
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
Cardiovascular
DEVELOPMENT STAGE
?
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Clariscan™' (6).Open this link in a new window

 
Further Reading:
  News & More:
GE Healthcare expands MRI contrast media product range in Europe with launch of macrocyclic agent ClariscanTM
Wednesday, 1 March 2017   by www.businesswire.com    
GE Healthcare announces FDA approval of macrocyclic MRI contrast agent Clariscan
Monday, 4 November 2019   by www.itnonline.com    
MRI Resources 
Breast MRI - DICOM - Education pool - Shielding - Abdominal Imaging - Open Directory Project
 
CoilForum -
related threadsInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
A coil consists of one or more loops of conductive wire, looped around the core of the coil. Coils are part of the hardware of MRI machines and are used to create a magnetic field or to detect a changing magnetic field by voltage induced in the wire. A coil is usually a physically small antenna.
The perfect coil produces a uniform magnetic field without significant radiation.
Different types of MRI coils are used in MR systems:
Gradient coils are used to produce controlled variations in the main magnetic field (B0) to provide spatial localization of the signals and to apply reversal pulses in some imaging techniques.
MR imaging radio frequency coils to receive and/or transmit the RF signal.
Shim coils provide auxiliary magnetic fields in order to compensate for inhomogeneities in the main magnetic field of the MRI machine.

See also Gradient Coil, Radio Frequency Coil, Hardware and Coil Loading.

See also the related POLL result: '3rd party coils are better than the original manufacturer coils'
spacer

• View the DATABASE results for 'Coil' (193).Open this link in a new window


• View the NEWS results for 'Coil' (11).Open this link in a new window.
 
Further Reading:
  News & More:
3T MRI-Compatible Small Body Array Gets FDA Nod
Monday, 15 January 2024   by www.diagnosticimaging.com    
High-field MRI Coils – that work, superbly, even at 750 MHz
   by www.dotynmr.com    
New superconducting coil improves MRI performance
Wednesday, 20 July 2016   by www.eurekalert.org    
First European fully superconductive coil reaching a magnetic field of 25 Tesla produced
Wednesday, 8 June 2016   by www.news-medical.net    
ScanMed Introduces a Groundbreaking New Orbit and Mandible Array to the MRI Market
Wednesday, 26 March 2014   by www.digitaljournal.com    
MRI coil optimized for imaging of infants gets FDA clearance
Tuesday, 17 April 2012   by www.medcitynews.com    
Low-profile MRI coil company inching toward commercialization
Wednesday, 21 December 2011   by www.medcitynews.com    
High-Resolution Uniform MR Imaging of Finger Joints Using a Dedicated RF Coil at 3 Tesla
Sunday, 31 January 2010   by www.ncbi.nlm.nih.gov    
DOTmed Industry Sector Report: MRI Coil Sales & Service Companies
Thursday, 13 December 2007   by www.dotmed.com    
MRI Resources 
Cochlear Implant - Shoulder MRI - Examinations - Guidance - Nerve Stimulator - Health
 
previous      6 - 10 (of 44)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]