Result : Searchterm 'Chemical Shift Imaging' found in 1 term [] and 11 definitions [], (+ 8 Boolean[] results
previous     16 - 20 (of 20)     
Result Pages : [1]  [2 3]  [4]
Searchterm 'Chemical Shift Imaging' was also found in the following services: 
spacer
News  (2)  Resources  (2)  
 
Magnetic Resonance SpectroscopyMRI Resource Directory:
 - Spectroscopy pool -
 
(MRS / MRSI - Magnetic Resonance Spectroscopic Imaging) A method using the NMR phenomenon to identify the chemical state of various elements without destroying the sample. MRS therefore provides information about the chemical composition of the tissues and the changes in chemical composition, which may occur with disease processes.
Although MRS is primarily employed as a research tool and has yet to achieve widespread acceptance in routine clinical practice, there is a growing realization that a noninvasive technique, which monitors disease biochemistry can provide important new information for the clinician.
The underlying principle of MRS is that atomic nuclei are surrounded by a cloud of electrons, which very slightly shield the nucleus from any external magnetic field. As the structure of the electron cloud is specific to an individual molecule or compound, then the magnitude of this screening effect is also a characteristic of the chemical environment of individual nuclei.
In view of the fact that the resonant frequency is proportional to the magnetic field that it experiences, it follows that the resonant frequency will be determined not only by the external applied field, but also by the small field shift generated by the electron cloud. This shift in frequency is called the chemical shift (see also Chemical Shift). It should be noted that chemical shift is a very small effect, usually expressed in ppm of the main frequency. In order to resolve the different chemical species, it is therefore necessary to achieve very high levels of homogeneity of the main magnetic field B0. Spectra from humans usually require shimming the magnet to approximately one part in 100. High resolution spectra of liquid samples demand a homogeneity of about one part in 1000.
In addition to the effects of factors such as relaxation times that can affect the NMR signal, as seen in magnetic resonance imaging, effects such as J-modulation or the transfer of magnetization after selective excitation of particular spectral lines can affect the relative strengths of spectral lines.
In the context of human MRS, two nuclei are of particular interest - H-1 and P-31. (PMRS - Proton Magnetic Resonance Spectroscopy) PMRS is mainly employed in studies of the brain where prominent peaks arise from NAA, choline containing compounds, creatine and creatine phosphate, myo-inositol and, if present, lactate; phosphorus 31 MR spectroscopy detects compounds involved in energy metabolism (creatine phosphate, adenosine triphosphate and inorganic phosphate) and certain compounds related to membrane synthesis and degradation. The frequencies of certain lines may also be affected by factors such as the local pH. It is also possible to determine intracellular pH because the inorganic phosphate peak position is pH sensitive.
If the field is uniform over the volume of the sample, "similar" nuclei will contribute a particular frequency component to the detected response signal irrespective of their individual positions in the sample. Since nuclei of different elements resonate at different frequencies, each element in the sample contributes a different frequency component. A chemical analysis can then be conducted by analyzing the MR response signal into its frequency components.

See also Spectroscopy.
spacer
 
• Related Searches:
    • Shimming
    • Point Resolved Spectroscopy
    • Brain MRI
    • Nuclear Magnetic Resonance
    • Magnitude
 
Further Reading:
  News & More:
Accuracy of Proton Magnetic Resonance Spectroscopy in Distinguishing Neoplastic From Non-neoplastic Brain Lesions
Saturday, 2 December 2023   by www.cureus.com    
MRI Resources 
Diffusion Weighted Imaging - Stimulator pool - PACS - Equipment - Quality Advice - MRCP
 
Opposed Phase ImageInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
An image in which the signal from two spectral components (such as fat and water) is 180° out of phase and leads to destructive interference in a voxel.
Since fat precesses slower than water, based on their chemical shift, their signals will decay and precess in the transverse plane at different frequencies. When the phase of the TE becomes opposed (180°), their combined signal intensities subtract with each other in the same voxel, producing a signal void or dark band at the fat/water interface of the tissues being examined.
Opposed phase gradient echo imaging for the abdomen is a lipid-type tissue sensitive sequence particularly for the liver and adrenal glands, which puts a signal intensity around abnormal water-based tissues or lesions that are fatty. Due to the increased sensitivity of opposed phase, the tissue visualization increases the lesion-to-liver contrast and exhibits more signal intensity loss in tissues containing small amounts of lipids compared to a spin echo T1 with fat suppression. Using an opposed phase gradient echo also provides the ability to differentiate various pathologies in the brain, including lipids, methaemoglobin, protein, calcifications and melanin.

See also Out of Phase, and Dixon.
 
Images, Movies, Sliders:
 MRI Liver Out Of Phase  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'Opposed Phase Image' (5).Open this link in a new window

 
Further Reading:
  News & More:
Adrenal Myelolipoma
Tuesday, 19 June 2001   by www.emedicine.com    
Iron overload: accuracy of in-phase and out-of-phase MRI as a quick method to evaluate liver iron load in haematological malignancies and chronic liver disease
Friday, 1 June 2012   by www.ncbi.nlm.nih.gov    
MRI Resources 
Cochlear Implant - Libraries - Journals - Education pool - Implant and Prosthesis - DICOM
 
Spectroscopy
 
Edward Purcell and Felix Bloch discovered the basic of spectroscopy in 1946 (see MRI History). Nuclear magnetic resonance spectroscopy (NMR Spectroscopy or MRS) is an analytical tool, based on nuclei that have a spin (nuclei with an odd number of neutrons and/or protons) like 1H, 13C, 17O, 19F, 31P etc.
Through nuclear magnetic principles as precession, chemical shift, spin spin coupling etc., the analysis of the content, purity, and molecular structure of a sample is possible. The spectrum produced by this process contains a number of peaks; the highs and the positions of these peaks allow the exact analysis. Unknown compounds can be matched against spectral libraries. Even very complex organic compounds as enzymes and proteins can be determined. For the wide uses of NMR spectroscopy (from mineralogy to medicine) there is a variety of different techniques available.
See Spectroscopic Imaging Techniques.
spacer

• View the DATABASE results for 'Spectroscopy' (90).Open this link in a new window


• View the NEWS results for 'Spectroscopy' (3).Open this link in a new window.
 
Further Reading:
  Basics:
MR Spectroscopy May Help Avoid Invasive Procedures And Treatments For Recurrent Brain Lesions
Wednesday, 11 February 2009   by www.sciencedaily.com    
MRI spectroscopy is highly sensitive for lipid-soluble metabolites from UC-MSCs
Monday, 9 September 2013   by phys.org    
  News & More:
Pioneering MRI imaging method captures brain glucose metabolism without the need for administration of radioactive substances
Friday, 28 April 2023   by www.eurekalert.org    
New quantum sensing technique allows high-resolution nuclear magnetic resonance spectroscopy
Wednesday, 17 June 2020   by phys.org    
MR Spectroscopy Detects Biochemical Alterations in Pre-Invasive Breast Cancer Patients
Wednesday, 11 March 2015   by radiationtherapynews.com    
MR Spectroscopy Shows Differences in Brains of Preterm Infants
Monday, 25 November 2013   by www.digitaljournal.com    
Proton Magnetic Resonance Spectroscopy and MRI Reveal No Evidence for Brain Mitochondrial Dysfunction in Children with Autism Spectrum Disorder.
Wednesday, 16 March 2011   by leftbrainrightbrain.co.uk    
Magnetic resonance spectroscopy for breast cancer
Wednesday, 11 July 2007   by www.news-medical.net    
Searchterm 'Chemical Shift Imaging' was also found in the following services: 
spacer
News  (2)  Resources  (2)  
 
Spectroscopic Imaging Techniques
 
For the wide uses of NMR spectroscopy (from mineralogy to medicine) there is a variety of different spectroscopic imaging techniques available.
A short listing of the most frequent variations:
'One-dimensional NMR Spectroscopy (1D NMR) is attended to the spectra of (1H) Proton, 13Carbon etc., which in general is divided in continuous wave and pulse spectroscopy. General used to determine chemical structures. Proton nuclear magnetic resonance (1H-NMR) spectroscopy and carbon nuclear magnetic resonance (13C-NMR) spectroscopy are the most prominent techniques here.
'Two-dimensional NMR Spectroscopy' (2D NMR) is based on pulse spectroscopy. This technique is mostly used for the study of chemical interactions accompanied by magnetization transfer. Examples for more diversified spectroscopy techniques are based on homonuclear (COSY, TOCSY, 2D-INADEQUATE, NOESY, ROESY) or heteronuclear correlation (HSQC, HMQC, HMBC).
'Solid State NMR Spectroscopy' analyzes samples with little or no molecular mobility. Dipolar coupling and chemical shift anisotropy are the dominating nuclear physical effects here. Used for example in pharmaceutical analysis.
'Solution State NMR Spectroscopy' is a technique to analyze the structure of samples with a high degree of molecular mobility as polymers, proteins, nucleic acids etc.
spacer

• View the DATABASE results for 'Spectroscopic Imaging Techniques' (2).Open this link in a new window

 
Further Reading:
  Basics:
Chemical Applications of NMR
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Automated analysis of the total choline resonance peak in breast proton magnetic resonance spectroscopy
Wednesday, 4 October 2023   by analyticalsciencejournals.onlinelibrary.wiley.com    
New Brain Imaging Technique Identifies Previously Undetected Epileptic Seizure Sites
Friday, 13 November 2015   by www.newswise.com    
Proton MR Spectroscopic Imaging without Water Suppression1
2000   by radiology.rsnajnls.org    
MRI Resources 
Collections - NMR - Pathology - Functional MRI - Mobile MRI Rental - Societies
 
Field StrengthForum -
related threads
 
In every MR examination, a large static magnetic field is applied. Field strengths for clinical equipment can vary between 0.2 and 3 T; experimental imaging units have a field strength of up to 11 T, depending on the MRI equipment used. In MRS, field strengths up to 12 T are currently used. The field strength of the magnet will influence the quality of the MR image regarding chemical shift artifacts, the signal to noise ratio (SNR), motion sensitivity and susceptibility artifacts.

See also the related poll result: 'In 2010 your scanner will probably work with a field strength of'
spacer

• View the DATABASE results for 'Field Strength' (123).Open this link in a new window


• View the NEWS results for 'Field Strength' (2).Open this link in a new window.
 
Further Reading:
  Basics:
What affects the strength of a magnet?
   by my.execpc.com    
Magnetic Field of the Strongest Magnet
2003   by hypertextbook.com    
  News & More:
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
Low Power MRI Helps Image Lungs, Brings Costs Down
Thursday, 10 October 2019   by www.medgadget.com    
Opportunities in Interventional and Diagnostic Imaging by Using High-performance Low-Field-Strength MRI
Tuesday, 1 October 2019   by pubs.rsna.org    
Low-field MRI: An MR physics perspective
Sunday, 13 January 2019   by onlinelibrary.wiley.com    
Ultra-high-field MRI allows for earlier diagnosis of multiple sclerosis
Friday, 4 May 2007   by www.eurekalert.org    
Low-intensity MRI takes first scan of a human brain
Wednesday, 14 November 2007   by technology.newscientist.com    
MRI Resources 
DICOM - Non-English - Safety Training - Implant and Prosthesis pool - Movies - Cochlear Implant
 
previous      16 - 20 (of 20)     
Result Pages : [1]  [2 3]  [4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]