Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Contrast' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Contrast' found in 43 terms [] and 326 definitions []
previous     76 - 80 (of 369)     next
Result Pages : [1 2 3 4 5 6 7 8 9]  [10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Contrast' was also found in the following services: 
spacer
News  (140)  Resources  (28)  Forum  (72)  
 
Gadovist®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Gadovist® is an extracellular, neutral macrocyclic (gadolinium (Gd) complex) MRI contrast agents for central nervous system indications, particularly suited for studies in which high doses are required or advantageous. Gadovist® (also Gadograf) was available in two concentrations, currently only Gadovist® 1.0 is marketed.
The product was approved in Switzerland in 1999 and in Germany in 2000. Gadovist® 1.0 is in USA currently in the drug development and approval process, particularly for magnetic resonance angiography.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Paramagnetic Contrast Agents and Gadobutrol.
Drug Information and Specification
NAME OF COMPOUND
Gadobutrol, Gd-BT-DO3A
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.6, B0=1.0 T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
OSMOLALITY
557 and 1603 mosm/kgH2O
CONCENTRATION
1 mol/L
DOSAGE
0.1mmol/kg
PREPARATION
Finished product
INDICATION
Central nervous system / whole body
DEVELOPMENT STAGE
For sale / submit for approval
DISTRIBUTOR
See below
PRESENTATION
Vials of 15, 30 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Gadovist®
Submit for approval
Japan
Gadovist®
EU
Gadovist®
for sale
Australia
Gadovist®
for sale
spacer
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Gadograf, Gadovist
Friday, 13 April 2007   by www.ema.europa.eu    
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
FDA approves Bayer's Gadavist® (gadobutrol) injection as the first magnetic resonance contrast agent for pediatric patients less than 2 years of age
Monday, 5 January 2015   by www.prnewswire.com    
New data presented at RSNA on use of Bayer's Gadavist® (gadobutrol) injection in children less than 2 years of age
Wednesday, 3 December 2014   by www.prnewswire.com    
Searchterm 'Contrast' was also found in the following services: 
spacer
Radiology  (106) Open this link in a new windowUltrasound  (149) Open this link in a new window
LiposomesInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Generic name: Liposomes, central moiety: different, contrast effect: paramagnetic, distribution: different
Liposomes are lipid containing nanoparticles, or fat molecules, surrounding a water core. Liposomes were the first type of nanoparticles created to be used as carriers for lipophilic MRI contrast agents with novel characteristics.
Liposomes loaded with gadolinium-containing chelates have potential as blood pool agents, caused by modifications of the surface (e.g., with polyethylene glycol) leading to longer blood retention times.
The incorporation of contrast agents into either the the bilayer membrane or the aqueous inner cavity is possible. These MRI contrast agents has been used to image the lymph nodes using liposomes containing Gd-DTPA as well as dextran coated iron oxide particles.
To image the liver or the hepatobiliary system, liposomes containing Gd-HPDO3A, or MnDPDP, have been tested.
Liposomes containing gadolinium were conjugated to antibodies and targeted to a specific organ system.
A method of targeting tumors with ultrasound that also uses MRI to watch the cell destroying, uses liposomes loaded with cytotoxic drugs and also with gadolinium to make them show up in MRI. As well as used as an imaging technique, ultrasound can also be used to destroy cancer cells. Once the drugs have been administered, focusing the ultrasound on the target area makes blood vessels permeable. The liposomes leak out of the blood vessel into the target area, watched by MRI, where the cytotoxic drug can then go to work.

See also Memosomes, Superparamagnetic Iron Oxide, Classifications, Characteristics, etc. and Mangafodipir Trisodium.
spacer

• View the DATABASE results for 'Liposomes' (6).Open this link in a new window


• View the NEWS results for 'Liposomes' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Novel Agent for Lymph Node Imaging and Targeted Gene Therapy
1997   by cbcrp.org.127.seekdotnet.com    
DELIVERY AND ACTIVATION OF CONTRAST AGENTS FOR MAGNETIC RESONANCE IMAGING(.pdf)
   by thesis.library.caltech.edu    
New MRI Contrast Agent Under Development
Friday, 16 January 2009   by www.medgadget.com    
New Method Combines MRI, HIFU, Temperature-Sensitive Liposomes for Chemo Delivery Directly to Tumor
Wednesday, 9 February 2011   by www.medgadget.com    
  News & More:
Specialized MRI sensor can detect light deep within tissues
Thursday, 22 December 2022
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Molecular Magnetic Resonance Imaging(.pdf)
2005   by www.medical.siemens.com    
MRI Resources 
Stent - Manufacturers - Online Books - MR Guided Interventions - Case Studies - Absorption and Emission
 
Lung ImagingMRI Resource Directory:
 - Lung Imaging -
 
Lung imaging is furthermore a challenge in MRI because of the predominance of air within the lungs and associated susceptibility issues as well as low signal to noise of the inflated lung parenchyma. Cardiac and respiratory triggered or breath hold sequences allow diagnostic imaging, however a comparable image quality with computed tomography is still difficult to achieve.
Assumptions for lung MRI:
•
Low signal to noise ratio of the inherently low lung proton density.
•
Cardiac and respiratory motion artifacts.
•
Magnetic susceptibility effects of large magnetic field gradients.
•
Very short transverse relaxation times and significant diffusion yielding short T2 (30-70 msec), short T2* (1-3 msec), and additional long T1 relaxation times (1300-1500 msec).
•
The extreme short T2 values are responsible for a fast signal decay during a single shot readout, resulting in blurring.

The current trends in MRI are the use of new imaging technologies and increasingly powerful magnetic fields. Among these technologies are parallel imaging techniques as well as ventilation agents like hyperpolarized helium for the use as an inert inhalational contrast agent to study lung ventilation properties. With hyperpolarized gases clear images of the lungs can be obtained without using a large magnetic field (see also back projection imaging). Single shot sequences (e.g. TSE or Half Fourier Acquisition Single Shot Turbo Spin Echo HASTE) used in lung MR imaging benefits from parallel imaging techniques due to reduced relaxation time effects during the echo train and therefore reduced image blurring as well as reduced motion artifacts.
In the future, more effective contrast agents may provide an alternative solution to the need for high field MRI. Dynamic contrast enhanced MRI perfusion has demonstrated a potential in the diagnosis of pulmonary embolism or to characterize lung cancer and mediastinal tumors. 3D contrast enhanced magnetic resonance angiography of the thoracic vessel.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
 
Images, Movies, Sliders:
 Anatomic Imaging of the Lungs  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 MRI Thorax Basal Plane  Open this link in a new window
 
Radiology-tip.comradLung Scintigraphy
spacer

• View the DATABASE results for 'Lung Imaging' (7).Open this link in a new window


• View the NEWS results for 'Lung Imaging' (3).Open this link in a new window.
 
Further Reading:
  Basics:
A safer approach for diagnostic medical imaging
Monday, 29 September 2014   by www.eurekalert.org    
Parallel Lung Imaging(.pdf)
  News & More:
Chest MRI a viable alternative to chest CT in COVID-19 pneumonia follow-up
Monday, 21 September 2020   by www.healthimaging.com    
CT Imaging Features of 2019 Novel Corona virus (2019-nCoV)
Tuesday, 4 February 2020   by pubs.rsna.org    
Polarean Imaging Phase III Trial Results Point to Potential Improvements in Lung Imaging
Wednesday, 29 January 2020   by www.diagnosticimaging.com    
Low Power MRI Helps Image Lungs, Brings Costs Down
Thursday, 10 October 2019   by www.medgadget.com    
Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence
Thursday, 11 July 2019   by www.sciencedirect.co    
Researchers Review Importance of Non-Invasive Imaging in Diagnosis and Management of PAH
Wednesday, 11 March 2015   by lungdiseasenews.com    
New MRI Approach Reveals Bronchiectasis' Key Features Within the Lung
Thursday, 13 November 2014   by lungdiseasenews.com    
MRI techniques improve pulmonary embolism detection
Monday, 19 March 2012   by medicalxpress.com    
  News & More:
Partnership with VIDA to streamline adoption of advanced MRI of the lungs
Monday, 11 September 2023   by www.itnonline.com    
Searchterm 'Contrast' was also found in the following services: 
spacer
News  (140)  Resources  (28)  Forum  (72)  
 
MRI SafetyMRI Resource Directory:
 - Safety -
 
There are different types of contraindications that would prevent a person from being examined with an MRI scanner. MRI systems use strong magnetic fields that attract any ferromagnetic objects with enormous force. Caused by the potential risk of heating, produced from the radio frequency pulses during the MRI procedure, metallic objects like wires, foreign bodies and other implants needs to be checked for compatibility. High field MRI requires particular safety precautions. In addition, any device or MRI equipment that enters the magnet room has to be MR compatible. MRI examinations are safe and harmless, if these MRI risks are observed and regulations are followed.

Safety concerns in magnetic resonance imaging include:
•
the magnetic field strength;
•
possible 'missile effects' caused by magnetic forces;
•
the potential for heating of body tissue due to the application of the radio frequency energy;
•
the effects on implanted active devices such as cardiac pacemakers or insulin pumps;
•
magnetic torque effects on indwelling metal (clips, etc.);
•
the audible acoustic noise;
•
danger due to cryogenic liquids;
•
the application of contrast medium;
mri safety guidance
MRI Safety Guidance
It is important to remember when working around a superconducting magnet that the magnetic field is always on. Under usual working conditions the field is never turned off. Attention must be paid to keep all ferromagnetic items at an adequate distance from the magnet. Ferromagnetic objects which came accidentally under the influence of these strong magnets can injure or kill individuals in or nearby the magnet, or can seriously damage every hardware, the magnet itself, the cooling system, etc.. See MRI resources Accidents.
The doors leading to a magnet room should be closed at all times except when entering or exiting the room. Every person working in or entering the magnet room or adjacent rooms with a magnetic field has to be instructed about the dangers. This should include the patient, intensive-care staff, and maintenance-, service- and cleaning personnel, etc..
The 5 Gauss limit defines the 'safe' level of static magnetic field exposure. The value of the absorbed dose is fixed by the authorities to avoid heating of the patient's tissue and is defined by the specific absorption rate. Leads or wires that are used in the magnet bore during imaging procedures, should not form large-radius wire loops. Leg-to-leg and leg-to-arm skin contact should be prevented in order to avoid the risk of burning due to the generation of high current loops if the legs or arms are allowed to touch. The patient's skin should not be in contact with the inner bore of the magnet.
The outflow from cryogens like liquid helium is improbable during normal operation and not a real danger for patients.
The safety of MRI contrast agents is tested in drug trials and they have a high compatibility with very few side effects. The variations of the side effects and possible contraindications are similar to X-ray contrast medium, but very rare. In general, an adverse reaction increases with the quantity of the MRI contrast medium and also with the osmolarity of the compound.

See also 5 Gauss Fringe Field, 5 Gauss Line, Cardiac Risks, Cardiac Stent, dB/dt, Legal Requirements, Low Field MRI, Magnetohydrodynamic Effect, MR Compatibility, MR Guided Interventions, Claustrophobia, MRI Risks and Shielding.
Radiology-tip.comradRadiation Safety,  Ionizing Radiation
spacer
Medical-Ultrasound-Imaging.comUltrasound Safety,  Absorbed Dose
spacer

• View the DATABASE results for 'MRI Safety' (42).Open this link in a new window


• View the NEWS results for 'MRI Safety' (13).Open this link in a new window.
 
Further Reading:
  Basics:
MRI Safety
2001   by www.fda.gov    
What MRI Sequences Produce the Highest Specific Absorption Rate (SAR), and Is There Something We Should Be Doing to Reduce the SAR During Standard Examinations?
Thursday, 16 April 2015   by www.ajronline.org    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
  News & More:
How safe is 7T MRI for patients with neurosurgical implants?
Thursday, 17 November 2022   by healthimaging.com    
Newer Heart Devices Safe During MRI
Monday, 23 August 2004   by www.hospimedica.com    
Study: Face Masks Unsafe in MRI Machines
Wednesday, 13 July 2022   by www.laboratoryequipment.com    
COVID-19: Attention shifts to MRI infection control
Thursday, 9 July 2020   by https://www.auntminnieeurope.com/index.aspx?sec=ser§sub=def§pag=dis§ItemID=619012    
FDA Releases New Guidance On Establishing Safety, Compatibility Of Passive Implants In MR Environments
Tuesday, 16 December 2014   by www.meddeviceonline.com    
Modern Implantable Heart Devices Safe For Use In MRI Scans
Wednesday, 16 March 2005   by www.sciencedaily.com    
Searchterm 'Contrast' was also found in the following services: 
spacer
Radiology  (106) Open this link in a new windowUltrasound  (149) Open this link in a new window
MS-325Forum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MS-325 is the formerly code name of gadofosveset trisodium (new trade name Vasovist). MS-325 belongs to a new class of blood pool agents for magnetic resonance angiography (MRA) to diagnose vascular disease. Gadofosveset trisodium has ten times the signal-enhancing power of existing contrast agents as well as prolonged retention in the blood. This enables the rapid acquisition of high resolution MRA's using standard MRI machines.
Gadofosveset trisodium, which is gadolinium-based, stays in the blood stream as a result of transient binding to albumin. Albumin binding offers an additional benefit beyond localization in the blood pool. The contrast agent begins to spin much more slowly, at the rate albumin spins, causing a relaxivity gain that produces a substantially brighter signal than would be possible with freely circulating gadolinium. MS-325 is an intravascular contrast agent intended for use in MRI as an aid in diagnosing aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease (PVD) or abdominal aortic aneurysm (AAA).
Currently clinical trials completed for peripheral vascular disease and coronary artery disease. Additional trials are also being conducted to evaluate MS-325 as an aid in diagnosing breast cancer and suggested that it might be feasible to combine the use of MS-325, injected during peak stress, with delayed high-resolution imaging to identify myocardial perfusion defects.
Vasovist (MS-325) would compete with the contrast agents Ferumoxytol (Code 7228) from AMAG Pharmaceuticals, Inc. and NC100150 Injection from Nycomed Amersham, but their further development is uncertain.
Partners in development: EPIX Pharmaceuticals, Inc., Mallinckrodt Inc., and Bayer Schering Pharma AG. Bayer Schering Pharma has the worldwide marketing rights for the product.
Formerly known under the Mallinckrodt trademark name, AngioMARK®.

See also Classifications, Characteristics, etc.
spacer

• View the DATABASE results for 'MS-325' (4).Open this link in a new window


• View the NEWS results for 'MS-325' (10).Open this link in a new window.
 
Further Reading:
  News & More:
EPIX Medical's new multimedia Web site features AngioMARK images in 3D
Friday, 5 March 1999
MRI technology combined with contrast agent optimizes diagnosis of cardiovascular disease
1999
MRI Resources 
Portals - Resources - Pregnancy - Contrast Enhanced MRI - RIS - General
 
previous      76 - 80 (of 369)     next
Result Pages : [1 2 3 4 5 6 7 8 9]  [10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising