Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Contrast Agents' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Contrast Agents' found in 17 terms [] and 118 definitions []
previous     56 - 60 (of 135)     next
Result Pages : [1 2 3 4]  [5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Contrast Agents' was also found in the following services: 
spacer
News  (49)  Resources  (7)  Forum  (8)  
 
Necrosis Avid Contrast AgentInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
(NACA) Some porphyrin (e.g. Gadophrin-2) and non-porphyrin (e.g. CEIII-60) paramagnetic chelates are able to specifically accumulate in nonviable tissues and can be applied as a MRI contrast agent for acute myocardial infarction and therapeutic necrosis. This function of necrosis avid contrast agents is a unique pathological targetability. These agents can also be exploited for multipurpose applications, because NACAs also bear other common properties including early systemic distribution, albumin binding, hepatocellular uptake and renal elimination.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the NEWS results for 'Necrosis Avid Contrast Agent' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Tumor-targeted MR Contrast Agents: Hype or Future Hope?
November 2004   by radiology.rsnajnls.org    
  News & More:
Rockland Technimed: Tissue Viability Imaging
Saturday, 15 December 2007   by www.onemedplace.com    
Searchterm 'Contrast Agents' was also found in the following services: 
spacer
Radiology  (46) Open this link in a new windowUltrasound  (75) Open this link in a new window
Oral Magnetic ParticlesInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(OMP) Various mixtures of gastrointestinal diamagnetic contrast agents for use as negative oral contrast agents to darken the bowel.
Drug Information and Specification
NAME OF COMPOUND
Barium suspensions, clay mineral particles, iron oxide crystals
DEVELOPER
CENTRAL MOIETY
Ba3+, Al3+, Si2+, Fe
CONTRAST EFFECT
T2, Predominantly negative enhancement
T2-shortening
PHARMACOKINETIC
CONCENTRATION
Various mixtures
DOSAGE
Depending on the mixture
PREPARATION
Depending on the product
INDICATION
Gastrointestinal bowel marking
DEVELOPMENT STAGE
No clinical development
DISTRIBUTOR
PRESENTATION

DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Oral Magnetic Particles' (4).Open this link in a new window

MRI Resources 
MRI Technician and Technologist Career - Libraries - Developers - Image Quality - MR Guided Interventions - Implant and Prosthesis pool
 
Paramagnetic Chemical Exchange Saturation TransferInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(PARACEST) The alteration of the proton density or total water signal changes contrast and can be detected by the MRI scanner. Paramagnetic chemical exchange saturation transfer contrast agents are based upon the magnetization transfer mechanism.
Lanthanide ion complexes formed with tetra-amide based ligands display unusually slow water exchange kinetics and this feature may be used to alter image contrast by applying a selective presaturation pulse in an imaging sequence. This results in chemical exchange saturation transfer (CEST) from the lanthanide-bound water to bulk water thereby altering image contrast.
Chemical Exchange Saturation Transfer (CEST) agents are a class of contrast agents that could potentially revolutionize the MRI field because of their improved sensitivity and can have a great impact on functional magnetic resonance imaging.
spacer
 
Further Reading:
  Basics:
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
  News & More:
New Brain Imaging Technique Identifies Previously Undetected Epileptic Seizure Sites
Friday, 13 November 2015   by www.newswise.com    
Non-invasive Imaging Method For Diagnosing Osteoarthritis Developed
Friday, 15 February 2008   by www.sciencedaily.com    
Searchterm 'Contrast Agents' was also found in the following services: 
spacer
News  (49)  Resources  (7)  Forum  (8)  
 
Short T1-Relaxation Gastrointestinal AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Protons in -CH2- groups, e.g., contained in fatty emulsions, mineral or vegetable oil or sucrose polyester, have a fast relaxation and short T1 time. These agents with short T1-relaxation, if used in gastrointestinal imaging, produce bright signal intensities in the intestine on T1 weighted sequences. Palatable oil emulsions can produce appropriate contrast opacification of the stomach as well as the small bowel, but caused by absorption in the distal small bowel these materials are not suitable for use in MRI colonoscopy.

See also Positive Oral Contrast Agents and Gastrointestinal Paramagnetic Contrast Agents.
 
Images, Movies, Sliders:
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Short T1-Relaxation Gastrointestinal Agents' (2).Open this link in a new window

Searchterm 'Contrast Agents' was also found in the following services: 
spacer
Radiology  (46) Open this link in a new windowUltrasound  (75) Open this link in a new window
Upperton LimitedMRI Resource Directory:
 - Developers -
 
www.upperton.com/products.htm Research Project Description
Lung Imaging X-ray and MRI contrast agents for lung MRI applications.
Blood Pool Imaging MRI contrast agents for vascular and targeted imaging.

Nuclear Imaging Agents based on recombinant human albumin for nuclear imaging.
Contact Information
MAIL
Upperton Limited
Dr Richard Johnson
PO Box 6861
Nottingham, NG2 5PF
Great Britain
PHONE
+44-(0)115-945-2378
FAX
+44-(0)115-945-2378
spacer
 
Further Reading:
  Basics:
Blood-Pool Imaging Using Technetium-99m-Labeled Liposomes(.pdf)
   by jnm.snmjournals.org    
MRI Resources 
Veterinary MRI - Safety Training - Supplies - Contrast Enhanced MRI - Pregnancy - Service and Support
 
previous      56 - 60 (of 135)     next
Result Pages : [1 2 3 4]  [5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]