Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Diffusion' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Diffusion' found in 8 terms [] and 36 definitions []
previous     31 - 35 (of 44)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9]
Searchterm 'Diffusion' was also found in the following services: 
spacer
News  (29)  Resources  (8)  Forum  (13)  
 
Lattice Index Map
 
This parametric images reflect the similarity between the anisotropic diffusion of each pixel and that of its neighbors.
spacer
 
Further Reading:
  News & More:
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Friday, 1 June 2007   by www.ajronline.org    
Searchterm 'Diffusion' was also found in the following services: 
spacer
Radiology  (1) Open this link in a new windowUltrasound  (2) Open this link in a new window
Lung ImagingMRI Resource Directory:
 - Lung Imaging -
 
Lung imaging is furthermore a challenge in MRI because of the predominance of air within the lungs and associated susceptibility issues as well as low signal to noise of the inflated lung parenchyma. Cardiac and respiratory triggered or breath hold sequences allow diagnostic imaging, however a comparable image quality with computed tomography is still difficult to achieve.
Assumptions for lung MRI:
•
Low signal to noise ratio of the inherently low lung proton density.
•
Cardiac and respiratory motion artifacts.
•
Magnetic susceptibility effects of large magnetic field gradients.
•
Very short transverse relaxation times and significant diffusion yielding short T2 (30-70 msec), short T2* (1-3 msec), and additional long T1 relaxation times (1300-1500 msec).
•
The extreme short T2 values are responsible for a fast signal decay during a single shot readout, resulting in blurring.

The current trends in MRI are the use of new imaging technologies and increasingly powerful magnetic fields. Among these technologies are parallel imaging techniques as well as ventilation agents like hyperpolarized helium for the use as an inert inhalational contrast agent to study lung ventilation properties. With hyperpolarized gases clear images of the lungs can be obtained without using a large magnetic field (see also back projection imaging). Single shot sequences (e.g. TSE or Half Fourier Acquisition Single Shot Turbo Spin Echo HASTE) used in lung MR imaging benefits from parallel imaging techniques due to reduced relaxation time effects during the echo train and therefore reduced image blurring as well as reduced motion artifacts.
In the future, more effective contrast agents may provide an alternative solution to the need for high field MRI. Dynamic contrast enhanced MRI perfusion has demonstrated a potential in the diagnosis of pulmonary embolism or to characterize lung cancer and mediastinal tumors. 3D contrast enhanced magnetic resonance angiography of the thoracic vessel.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
 
Images, Movies, Sliders:
 Anatomic Imaging of the Lungs  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 MRI Thorax Basal Plane  Open this link in a new window
 
Radiology-tip.comradLung Scintigraphy
spacer

• View the DATABASE results for 'Lung Imaging' (7).Open this link in a new window


• View the NEWS results for 'Lung Imaging' (3).Open this link in a new window.
 
Further Reading:
  Basics:
A safer approach for diagnostic medical imaging
Monday, 29 September 2014   by www.eurekalert.org    
Parallel Lung Imaging(.pdf)
  News & More:
Chest MRI a viable alternative to chest CT in COVID-19 pneumonia follow-up
Monday, 21 September 2020   by www.healthimaging.com    
CT Imaging Features of 2019 Novel Corona virus (2019-nCoV)
Tuesday, 4 February 2020   by pubs.rsna.org    
Polarean Imaging Phase III Trial Results Point to Potential Improvements in Lung Imaging
Wednesday, 29 January 2020   by www.diagnosticimaging.com    
Low Power MRI Helps Image Lungs, Brings Costs Down
Thursday, 10 October 2019   by www.medgadget.com    
Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence
Thursday, 11 July 2019   by www.sciencedirect.co    
Researchers Review Importance of Non-Invasive Imaging in Diagnosis and Management of PAH
Wednesday, 11 March 2015   by lungdiseasenews.com    
New MRI Approach Reveals Bronchiectasis' Key Features Within the Lung
Thursday, 13 November 2014   by lungdiseasenews.com    
MRI techniques improve pulmonary embolism detection
Monday, 19 March 2012   by medicalxpress.com    
  News & More:
Partnership with VIDA to streamline adoption of advanced MRI of the lungs
Monday, 11 September 2023   by www.itnonline.com    
MRI Resources 
Spine MRI - Used and Refurbished MRI Equipment - MR Guided Interventions - Liver Imaging - Raman Spectroscopy - Pacemaker
 
Motion Probing Gradient
 
Many MR imaging techniques using Motion Probing Gradients (MPG's) such as Spin Echo (SE), Stimulated Echo (STE), Rapid Acquisition with Relaxation Enhancement (RARE), Turbo-SE, and SE-EPI (Echo Planar Imaging for Spin echo acquisition), Spiral imaging, and Projection reconstruction including PROPELLER are applicable to DWI. In diffusion weighted imaging, 2 MPG's are required. The MPG's are put symmetrically into both sides of a 180° or 90° RF pulse to change the direction of the magnetized spin in the X-Y plane for spin echo or stimulated echo acquisition.
spacer

• View the DATABASE results for 'Motion Probing Gradient' (2).Open this link in a new window

 
Further Reading:
  Basics:
Diffusion Imaging: From Basic Physics to Practical Imaging
1999   by ej.rsna.org    
  News & More:
Motion Compensation in MR Imaging
   by ccn.ucla.edu    
Searchterm 'Diffusion' was also found in the following services: 
spacer
News  (29)  Resources  (8)  Forum  (13)  
 
NC100150 InjectionInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: NC100150, PEG-feron, generic name: Feruglose, preliminary trade name: Clariscan™
NC100150 injection is the code name for an USPIO (ultrasmall superparamagnetic iron oxide) MRI contrast agent under development. Microvessel permeability depends on functional and morphologic characteristics of cancer vessels and on physicochemical properties of the injected contrast medium molecule.
USPIO particles have a favorable pharmacological and tolerance profile and are being tested clinically of the potential for the quantitative characterization of tumor microvasculature and specifically for measures of the microvessel permeability. Iron-based products take advantage of their large molecular size, which prevents diffusion into body tissues. These agents are disposed of by the liver and spleen as particulate matter.
NC100150 Injection (Nycomed Amersham, Amersham Health ) consists of USPIO particles that are composed of single crystals (4- to 7-nm diameter) and stabilized with a carbohydrate polyethylene glycol (PEG) coat. The iron oxide particles have to be suspended in an isotonic glucose solution. The final diameter of an USPIO particle is approximately 20 nm. Blood pool half-life is more than two hours in humans; the particles are taken up by the mononuclear phagocyte system and distributed mainly to the liver and spleen.
NC100150 would compete with the contrast agents Ferumoxytol from AMAG Pharmaceuticals, Inc. and Vasovist™ from EPIX Pharmaceuticals, Inc., but at this time the development of NC100150 Injection/Clariscan™ is discontinued.
spacer

• View the DATABASE results for 'NC100150 Injection' (5).Open this link in a new window


• View the NEWS results for 'NC100150 Injection' (2).Open this link in a new window.
Searchterm 'Diffusion' was also found in the following services: 
spacer
Radiology  (1) Open this link in a new windowUltrasound  (2) Open this link in a new window
P760InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: P760, chemical compound: tetraazacyclododecanetetraacetic acid (DOTA), central moity: Gd
P760 (Guerbet SA) is a low-diffusion gadolinium complex with a macrocyclic core based on a tetraazacyclododecanetetraacetic acid (DOTA) structure, which is substituted with bulky hydrophilic groups. The relaxivity of P760 at 0.47 T is very high compared to Gd-DOTA.
spacer

• View the DATABASE results for 'P760' (2).Open this link in a new window


• View the NEWS results for 'P760' (1).Open this link in a new window.
 
Further Reading:
  News & More:
The Toolbox Indirectly, tissue is the issue
MRI Resources 
Pregnancy - Shielding - Stimulator pool - Breast Implant - PACS - Jobs pool
 
previous      31 - 35 (of 44)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]