Echo Train
 
A series of 180° RF rephasing pulses and their corresponding echoes for a fast or turbo spin echo pulse sequence.

See Fast Spin Echo and Turbo Spin Echo Turbo Factor.
spacer
 
• Related Searches:
    • Asymmetrical Echoes
    • Number of Echoes
    • Lung Imaging
    • Fast Spin Echo
    • Slew Rate
 
Further Reading:
  Basics:
RARE
Monday, 3 December 2012   by www2.warwick.ac.uk    
Searchterm 'Echo' was also found in the following services: 
spacer
Radiology  (4) Open this link in a new windowUltrasound  (159) Open this link in a new window
Field EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(FE) Echo produced by reversing the direction of the magnetic field gradient to cancel out the position-dependent phase shifts that have accumulated due to the gradient.

See also Gradient Echo Sequence.
spacer

• View the DATABASE results for 'Field Echo' (22).Open this link in a new window


• View the NEWS results for 'Field Echo' (1).Open this link in a new window.
MRI Resources 
MRI Training Courses - Guidance - Colonography - Nerve Stimulator - Collections - Breast Implant
 
Echo Offset
 
Echo offset is the time setting of spin echo and gradient echo to be not coincident and to generate phase differences between different spectral line signals (e.g., water and fat). The echo offset is the product of the frequency line difference and the time difference (TD) in the echo times and is equal to the magnitude of the result of the phase difference between two spectral lines. Phases may not change linearly with echo offset time in the presence of a large field inhomogeneity. An echo offset excitation pulse sequence can be used in the magnetic field mapping method, to generate maps from which the standard deviation of the phase difference can be calculated.
spacer
 
Further Reading:
  News & More:
T1rho-prepared balanced gradient echo for rapid 3D T1rho MRI
Monday, 1 September 2008   by www.ncbi.nlm.nih.gov    
A short-TR single-echo spin-echo breath-hold method for assessing liver T2
Sunday, 10 December 2023   by link.springer.com    
Searchterm 'Echo' was also found in the following services: 
spacer
News  (7)  Resources  (10)  Forum  (35)  
 
Echo Sharing
 
A measurement technique for double contrast sequences, whereat echoes that determines the image resolution are used in both raw data matrices.
spacer
Searchterm 'Echo' was also found in the following services: 
spacer
Radiology  (4) Open this link in a new windowUltrasound  (159) Open this link in a new window
Echo Spacing
 
Echo spacing is the distance in time between the echoes in multiple echo sequences like, e.g. echo planar imaging, fast spin echo. A short echo space produces compact sequence timing and less image artifacts. The shorter the rise time, the faster the gradients and therefore the echo spacing. Gradients with a shorter echo spacing will have a better resolution and more slices per TR.

See also Fast Spin Echo.
spacer

• View the DATABASE results for 'Echo Spacing' (6).Open this link in a new window

 
Further Reading:
  Basics:
Fast Spin Echo(.pdf)
Tuesday, 24 January 2006   by www.81bones.net    
MRI Resources 
Most Wanted - Safety Products - Quality Advice - - Blood Flow Imaging - Claustrophobia
 
previous      6 - 10 (of 262)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20]  [ ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]