Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Fourier Transformation' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Fourier Transformation' found in 8 terms [] and 31 definitions []
previous     26 - 30 (of 39)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
Searchterm 'Fourier Transformation' was also found in the following services: 
spacer
Forum  (1)  
 
Phase Encoding
 
The process of locating a MR signal by altering the phase of spins in one dimension with a pulsed magnetic field gradient along that dimension prior to the acquisition of the signal.
If a gradient field is briefly switched on and then off again at the beginning of the pulse sequence right after the radio frequency pulse, the magnetization of the external voxels will either precess faster or slower relative to those of the central voxels.
During readout of the signal, the phase of the xy-magnetization vector in different columns will thus systematically differ. When the x- or y- component of the signal is plotted as a function of the phase encoding step number n and thus of time n TR, it varies sinusoidally, fast at the left and right edges and slow at the center of the image. Voxels at the image edges along the phase encoding direction are thus characterized by a higher 'frequency' of rotation of their magnetization vectors than those towards the center.
As each signal component has experienced a different phase encoding gradient pulse, its exact spatial reconstruction can be specifically and precisely located by the Fourier transformation analysis. Spatial resolution is directly related to the number of phase encoding levels (gradients) used. The phase encoding direction can be chosen, e.g. whenever oblique MR images are acquired or when exchanging frequency and phase encoding directions to control wrap around artifacts.
spacer
 
• Related Searches:
    • Frequency Encoding
    • Spin
    • Pulse Sequence Timing Diagram
    • Alignment
    • Aliasing
 
Further Reading:
  Basics:
Magnetic resonance imaging
   by www.scholarpedia.org    
Aliasing or wrap around artifacts
Thursday, 31 March 2011   by de.slideshare.net    
Searchterm 'Fourier Transformation' was also found in the following services: 
spacer
Radiology  (3) Open this link in a new windowUltrasound  (5) Open this link in a new window
Pulsed MRInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
A technique that uses RF pulses and Fourier transformation of the MR signal; have largely replaced the older continuous wave techniques.
spacer
MRI Resources 
Databases - Open Directory Project - Services and Supplies - Software - IR - Lung Imaging
 
Quadrature Detection
 
Quadrature detection is used in magnetic resonance imaging as well as in Doppler ultrasound and is also called quadrature demodulation or phase quadrature technique.
With this phase sensitive demodulation technique the complex demodulated signal is separated into two components. One is called the real channel; the second part is called the imaginary channel and is located 90° away from the real channel. The signals from both channels are combined to produce a single set of quadrature detected real and imaginary spectra. In MRI, the parts of the demodulated MR signal are further processed by Fourier transformation analysis. All information on the MR signal components e.g. amplitude, phase, and frequency is given by this quadrature detection combined with Fourier analysis.
spacer

• View the DATABASE results for 'Quadrature Detection' (2).Open this link in a new window

Searchterm 'Fourier Transformation' was also found in the following services: 
spacer
Forum  (1)  
 
Reconstruction
 
The mathematical process by which the displayed image is produced from the raw k-space data obtained from the receiver circuitry, typically utilizing Fourier transformation and selective filtering.
spacer

• View the DATABASE results for 'Reconstruction' (55).Open this link in a new window


• View the NEWS results for 'Reconstruction' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Reconstructing MRI scans with AI promises to expand MRI access to more patients
Tuesday, 17 January 2023   by www.news-medical.net    
FDA clears 2D image-reconstruction product for 3D MRI
Friday, 30 September 2022   by radiologybusiness.com    
A practical guideline for T1 reconstruction from various flip angles in MRI
Saturday, 1 October 2016   by journals.sagepub.com    
Searchterm 'Fourier Transformation' was also found in the following services: 
spacer
Radiology  (3) Open this link in a new windowUltrasound  (5) Open this link in a new window
Rotating Frame Zeugmatography
 
Technique of MR imaging that uses a gradient of the RF excitation field (to give a corresponding variation of the flip angle along the gradient as a means of encoding the spatial location of spins in the direction of the RF field gradient) in conjunction with a static magnetic field gradient (to give spatial encoding in an orthogonal direction). It can be considered to be a form of Fourier transformation imaging.
spacer
MRI Resources 
Case Studies - Service and Support - MRI Training Courses - Lung Imaging - Used and Refurbished MRI Equipment - Supplies
 
previous      26 - 30 (of 39)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]