Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Gastrointestinal Imaging' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Gastrointestinal Imaging' found in 1 term [] and 6 definitions [], (+ 9 Boolean[] results
previous     6 - 10 (of 16)     next
Result Pages : [1]  [2]  [3 4]
Searchterm 'Gastrointestinal Imaging' was also found in the following service: 
spacer
Resources  (2)  
 
PerfluorochemicalsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Perfluorochemicals are fluorinated organic compounds. Perfluorochemicals can be used in gastrointestinal imaging as a negative contrast agent to reduce signal in the intestine. The MRI signal reduction is caused by the absence of mobile protons.
Perfluoroctylbromide (PFOB)(C8F17Br) is suitable for gastrointestinal use in humans; perfluorononane has been tested in animal models. PFOB is commercially available as Perflubron® (Imagent GI, Alliance). Benefits of this type of contrast media are biologically inertia, immiscibility with water, and a fast transit through the small intestine caused by low surface tension.
Fluosol-DA, a perfluorochemical emulsion has been tested in mice as a tumor specific agent for 19F-MRI.

See also Classifications, Characteristics, etc.
spacer
 
Further Reading:
  Basics:
Artifical Blood
   by medind.nic.in    
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
MRI Resources 
Case Studies - Mobile MRI - MRI Technician and Technologist Career - Guidance - Shielding - Collections
 
Short T1-Relaxation Gastrointestinal AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Protons in -CH2- groups, e.g., contained in fatty emulsions, mineral or vegetable oil or sucrose polyester, have a fast relaxation and short T1 time. These agents with short T1-relaxation, if used in gastrointestinal imaging, produce bright signal intensities in the intestine on T1 weighted sequences. Palatable oil emulsions can produce appropriate contrast opacification of the stomach as well as the small bowel, but caused by absorption in the distal small bowel these materials are not suitable for use in MRI colonoscopy.

See also Positive Oral Contrast Agents and Gastrointestinal Paramagnetic Contrast Agents.
 
Images, Movies, Sliders:
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Short T1-Relaxation Gastrointestinal Agents' (2).Open this link in a new window

MRI Resources 
Guidance - Non-English - Libraries - MRI Technician and Technologist Jobs - Cochlear Implant - Implant and Prosthesis pool
 
Alliance Pharmaceutical Corp.MRI Resource Directory:
 - Manufacturers -
 
www.allp.htm California-based research and development company. Alliance has several patents regarding 'microbubble' compositions such as Imagent® that are intended to enhance ultrasound imaging and Imagent GI as a gastrointestinal MRI contrast agent. Another product is Oxygent™, a synthetic 'blood substitute'.

MRI Contrast Agents:
Contact Information
MAIL
Alliance Pharmaceutical Corp.
6175 Lusk Blvd.
San Diego, CA 92121
USA
PHONE
+1-858-410-5200
FAX
+1-858-410-5161
spacer

• View the DATABASE results for 'Alliance Pharmaceutical Corp.' (2).Open this link in a new window

 
Further Reading:
  Basics:
Slumping MRI market prompts Alliance to halt GI contrast agent effort
Wednesday, 28 September 1994   by www.searchmedica.com    
Searchterm 'Gastrointestinal Imaging' was also found in the following service: 
spacer
Resources  (2)  
 
Pharmacyclics, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.pcyc.com Pharmacyclics is a pharmaceutical company developing novel agents to improve current therapeutic approaches to cancer, cardiovascular diseases, and inflammation. The company's proprietary products are derived from its core technology in biometallic chemistry. These products under development are based upon small molecules, which bind metals in a unique way and are capable of capturing and focusing forms of energy used in a variety of medical applications. The company has one product in registration with the FDA, Gadolite® Oral Suspension, a contrast agent for imaging the gastrointestinal tract; two products in clinical development, Gd-Tex (Motexafin gadolinium), a radiation sensitizer, Lu-Tex, a photosensitizer; and several compounds in preclinical development.

MRI Contrast Agents:
Contact Information
MAIL
Pharmacyclics Inc.
995 East Arques Avenue
94085 Sunnyvale, California
USA
PHONE
+1-408-774-0330
FAX
+1-408-774-0340
spacer

• View the DATABASE results for 'Pharmacyclics, Inc.' (2).Open this link in a new window


• View the NEWS results for 'Pharmacyclics, Inc.' (5).Open this link in a new window.
 
Further Reading:
  News & More:
Pharmacyclics Receives Non-Approvable Letter from the FDA for Xcytrin for the Treatment of Lung Cancer Brain Metastases
Friday, 21 December 2007   by www.prnewswire.com    
Texaphyrin Compounds Visualize Vulnerable Plaque
Friday, 4 June 2004   by www.hospimedica.com    
MRI Resources 
Equipment - Examinations - Musculoskeletal and Joint MRI - Veterinary MRI - - Case Studies
 
FerriSeltz®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A solution of ferric ammonium citrate (Geritol) used to enhance the delineation of the bowel. With T1 weighted magnetic resonance imaging (MRI) the predominantly positive enhancement helps to distinguish organs and tissues that are adjacent to the upper regions of the gastrointestinal tract. Product name found as both Ferriseltz® and FerriSeltz®.
Drug Information and Specification
NAME OF COMPOUND
DEVELOPER
CENTRAL MOIETY
Fe2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Paramagnetic
PHARMACOKINETIC
Gastrointestinal
PREPARATION
Dissolve
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Bags with powder
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
FerriSeltz®
for sale
spacer

• View the DATABASE results for 'FerriSeltz®' (4).Open this link in a new window

MRI Resources 
Mobile MRI - Lung Imaging - Distributors - Stimulator pool - Mass Spectrometry - Jobs
 
previous      6 - 10 (of 16)     next
Result Pages : [1]  [2]  [3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]