 'Gradient Spin Echo' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Gradient Spin Echo' found in 1 term [] and 1 definition [], (+ 19 Boolean[] results
1 - 5 (of 21)     next
Result Pages : [1]  [2 3 4 5]
Searchterm 'Gradient Spin Echo' was also found in the following service: 
spacer
News  (1)  
 
Turbo Gradient Spin EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
(TGSE / TurboGSE) A sequence with a combination of Gradient and Spin Echo Imaging. Additional gradient echoes are generated before and after each spin echo. The spin echoes are allocated to the center of the raw data matrix to give pure T2 contrast. The gradient echoes primarily determine the image resolution. If multiple image lines are obtained during a single echo, the imaging pulse sequence type is a TGSE pulse sequence. This sequence is very fast, fat is darker and more sensitive to susceptibility effects. Also called GRASE.
spacer
 
• Share the entry 'Turbo Gradient Spin Echo':  Facebook  Twitter  LinkedIn  
MRI Resources 
Blood Flow Imaging - Diffusion Weighted Imaging - Health - Abdominal Imaging - MRCP - Calculation
 
Time Echo
 
(TE) Time between middle of exciting (e.g., 90°) RF pulse and middle of spin echo production. For multiple echoes, use TE1, TE2, etc. When the RF spin echo and gradient echo are not coincident in time, TE refers to the time of the gradient spin echo. See also Echo Time.
spacer
MRI Resources 
MRI Training Courses - Movies - Claustrophobia - Education pool - Brain MRI - Cardiovascular Imaging
 
Gradient and Spin EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(GRASE) A hybrid sequence with a combination of gradient and spin echo sequences. If multiple image lines are obtained during a single echo, the imaging pulse sequence type is a GRASE sequence.

See Gradient Echo Sequence and Spin Echo Sequence.
spacer

• View the DATABASE results for 'Gradient and Spin Echo' (3).Open this link in a new window

 
Further Reading:
  Basics:
GRASE (Gradient- and Spin-Echo) MR of the Brain
   by www.ajnr.org    
  News & More:
Sequence for Philips(.pdf)
   by www.droid.cuhk.edu.hk    
Searchterm 'Gradient Spin Echo' was also found in the following service: 
spacer
News  (1)  
 
Steady State Gradient Echo with Spin Echo SamplingInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
(E-SHORT) A gradient echo sequence in which a non-zero steady state develops for transverse and longitudinal magnetization. The TR is shorter than the T1 and T2 times of the tissue.
See Gradient Echo Sequence and Steady State Free Precession.
spacer
MRI Resources 
Diffusion Weighted Imaging - Guidance - Breast Implant - Implant and Prosthesis - Mobile MRI Rental - Journals
 
Spin Echo SequenceInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
Spin Echo Timing Diagram (SE) The most common pulse sequence used in MR imaging is based of the detection of a spin or Hahn echo. It uses 90° radio frequency pulses to excite the magnetization and one or more 180° pulses to refocus the spins to generate signal echoes named spin echoes (SE).
In the pulse sequence timing diagram, the simplest form of a spin echo sequence is illustrated.
The 90° excitation pulse rotates the longitudinal magnetization (Mz) into the xy-plane and the dephasing of the transverse magnetization (Mxy) starts.
The following application of a 180° refocusing pulse (rotates the magnetization in the x-plane) generates signal echoes. The purpose of the 180° pulse is to rephase the spins, causing them to regain coherence and thereby to recover transverse magnetization, producing a spin echo.
The recovery of the z-magnetization occurs with the T1 relaxation time and typically at a much slower rate than the T2-decay, because in general T1 is greater than T2 for living tissues and is in the range of 100-2000 ms.
The SE pulse sequence was devised in the early days of NMR days by Carr and Purcell and exists now in many forms: the multi echo pulse sequence using single or multislice acquisition, the fast spin echo (FSE/TSE) pulse sequence, echo planar imaging (EPI) pulse sequence and the gradient and spin echo (GRASE) pulse sequence;; all are basically spin echo sequences.
In the simplest form of SE imaging, the pulse sequence has to be repeated as many times as the image has lines.
Contrast values:
PD weighted: Short TE (20 ms) and long TR.
T1 weighted: Short TE (10-20 ms) and short TR (300-600 ms)
T2 weighted: Long TE (greater than 60 ms) and long TR (greater than 1600 ms)
With spin echo imaging no T2* occurs, caused by the 180° refocusing pulse. For this reason, spin echo sequences are more robust against e.g., susceptibility artifacts than gradient echo sequences.

See also Pulse Sequence Timing Diagram to find a description of the components.
 
Images, Movies, Sliders:
 Shoulder Coronal T1 SE  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 Shoulder Axial T1 SE  Open this link in a new window
 MRI Orbita T1  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'Spin Echo Sequence' (24).Open this link in a new window

 
Further Reading:
  Basics:
Fast Spin Echo(.pdf)
Tuesday, 24 January 2006   by www.81bones.net    
Magnetic resonance imaging
   by www.scholarpedia.org    
FUNDAMENTALS OF MRI: Part I
   by www.e-radiography.net    
  News & More:
New MR sequence helps radiologists more accurately evaluate abnormalities of the uterus and ovaries
Thursday, 23 April 2009   by www.eurekalert.org    
MRI techniques improve pulmonary embolism detection
Monday, 19 March 2012   by medicalxpress.com    
MRI Resources 
MRI Technician and Technologist Jobs - Research Labs - Nerve Stimulator - Examinations - Colonography - Brain MRI
 
     1 - 5 (of 21)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]