Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'ProHance' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'ProHance' found in 1 term [] and 5 definitions []
1 - 5 (of 6)     next
Result Pages : [1]  [2]
MRI Resources 
Universities - Breast Implant - Brain MRI - Pregnancy - DICOM - Stimulator pool
 
ProHance®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
ProHance® consists of a nonionic gadolinium complex (Gadoteridol) used as a paramagnetic MR contrast agent.
ProHance® provides contrast enhancement of the brain, spine and surrounding tissues resulting in improved visualization (compared with unenhanced MRI) of lesions with abnormal vascularity or those thought to cause a disruption of the normal blood brain barrier. ProHance® can also be used for whole body contrast enhanced MRI including the head, neck, liver, breast, musculoskeletal system and soft tissue pathologies.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See Gadoteridol.
Drug Information and Specification
NAME OF COMPOUND
Gadoteridol, Gd-HP-DO3A
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.7, r2=4.8, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
630 mosm/kgH2O
CONCENTRATION
0.5 mol/L, 279.3mg/ml
DOSAGE
0.1 mmol Gd/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15 and 20 mL
Glass syringes of 5, 10, 15 and 17 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
EU
ProHance®
for sale
Australia
ProHance®
for sale
Japan
ProHance®
for sale
spacer
 
• Share the entry 'ProHance®':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Prohance Product Information
   by www.drugs.com    
  News & More:
RSNA Statement on Gadolinium-Based MR Contrast Agents
Thursday, 1 February 2018   by www.rsna.org    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MRI Resources 
Functional MRI - Patient Information - Hospitals - Contrast Enhanced MRI - Open Directory Project - Spectroscopy pool
 
Bracco Diagnostics, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.bdi.bracco.com The company is a member of the Bracco Group, a highly innovative healthcare group and world leader in global integrated solutions for the diagnostic medical imaging field. The Bracco Group is headquartered in Milan, Italy. Its North American operations consist of Bracco Diagnostics and Bracco Research USA, both located in Princeton, New Jersey. Bracco Diagnostics is one of the fastest growing developers and marketers of diagnostic pharmaceuticals in North America, with products for various imaging applications, including Isovue® (iopamidol - X-ray contrast agent), ProHance® (gadoteridol - MRI contrast agent), SonoVue® (ultrasound contrast agent) and nuclear medicine products.
Gadoteridol has been available in Europe and the USA for several years. Holder of the Marketing Authorization: Bracco International B.V. - Strawinskylaan 3051 - 1077 ZX Amsterdam The Netherlands. (Contact: Kirk Deeter, Phone: +NL-303-838-8708)

MRI Contrast Agents:
•
•
•
•
Contact Information
Please see Bracco Diagnostics, Inc.'s
spacer

• View the DATABASE results for 'Bracco Diagnostics, Inc.' (2).Open this link in a new window

 
Further Reading:
  News & More:
FDA Expands Pediatric Age Range for MultiHance Contrast Agent
Tuesday, 30 January 2018   by www.empr.com    
BRACCO DIAGNOSTICS' MULTIHANCE EARNS FDA APPROVAL
Wednesday, 24 November 2004   by salesandmarketingnetwork.com    
MRI Resources 
Quality Advice - Musculoskeletal and Joint MRI - Supplies - Portals - Open Directory Project - Cochlear Implant
 
GadoteridolInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Gd-HP-DO3A, generic name: Gadoteridol injection, chemical compound: Gd-1,4,7-tris(carbonylmethyl)-10-(2'-hydroxypropyl)-1,4,7,10-tetraazacyclododecane
(ProHance®) A nonionic MRI contrast agent with a low molecular weight complex of gadolinium (macrocyclic chelate, which tightly binds the Gd atom).
Gadoteridol does not cross the blood brain barrier. If the barrier is damaged, gadoteridol will penetrate into lesions such as tumors. It also highlights areas of increased vascularity so it has been used to improve the delimitation of lesions elsewhere in the body.
Apart from its paramagnetic effects, gadoteridol has no pharmacological activity in the body. After intravenous injection, most of the dose is excreted unchanged in the urine within 24 hours.

See also Contrast Agents and ProHance®.
spacer

• View the DATABASE results for 'Gadoteridol' (5).Open this link in a new window

 
Further Reading:
  Basics:
Prohance Product Information
   by www.drugs.com    
MRI Resources 
NMR - MRI Reimbursement - IR - Chemistry - Functional MRI - DICOM
 
Bracco-Eisai Co., Ltd.MRI Resource Directory:
 - Manufacturers -
 
Eisai Co., Ltd. (Tokyo, Japan, President: Haruo Naito) and Bracco-Eisai Co., Ltd. (Tokyo, Japan, President: Toshio Matsumoto) decided to withdraw the new drug application (NDA) of E7155 (gadobenate meglumine), since new indications are emerging for the product and additional clinical data was necessary to complete the targeting product competitive risk/benefit profile. The product is currently marketed in other countries, and both companies are discussing a future development plan in Japan.

MRI Contrast Agents:
Contact Information
MAIL
Bracco Eisai Co., Ltd.
2-6, Kohinata 4-chome, Bunkyo-ku, Tokyo, 112-0006
PHONE
+03-3817-3939
spacer

• View the DATABASE results for 'Bracco-Eisai Co., Ltd.' (2).Open this link in a new window

MRI Resources 
Musculoskeletal and Joint MRI - Services and Supplies - Lung Imaging - Education - Stent - Mass Spectrometry
 
Extracellular Fluid AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
The contrast agents are either renal or hepatically excreted media, which stay in the intravascular/extracellular tissue compartment. The enhancement in the blood continues for as long as the contrast agent remains in the blood stream.
E.g. Dotarem®, Magnevist®, Omniscan®, ProHance®.

See Contrast Medium, Contrast Agents and Blood Pool Agents.
spacer

• View the DATABASE results for 'Extracellular Fluid Agents' (2).Open this link in a new window

MRI Resources 
Blood Flow Imaging - Lung Imaging - NMR - Distributors - MRI Physics - MRI Technician and Technologist Jobs
 
     1 - 5 (of 6)     next
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]