Magnetic
Resonance -
Technology
Information
Portal |
Welcome to MRI Technology• |
|
|
| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | 'State Food and Drug Administration' | |
Result : Searchterm 'State Food and Drug Administration' found in 1 term [] and 1 definition [], (+ 1 Boolean[] results
| 1 - 3 (of 3) Result Pages : [1] | | | | Searchterm 'State Food and Drug Administration' was also found in the following services: | | | | |
| | |
State Food and Drug Administration | |
| |
|
(SFDA) The State Food and Drug Administration of the People's Republic of China was founded in November 2003 and is directly under the State Council. The State Food and Drug Administration is in charge of comprehensive supervision on the safety management of food, health food and cosmetics and is the competent authority of drug regulation. For drug or medical device registration please see the SFDA's Regulatory Guide.
The agency is China's equivalent of the US Food and Drug Administration.
| | | | • For this and other aspects of MRI safety see our InfoSheet about MRI Safety. | | | • Patient-related information is collected in our MRI Patient Information.
| | | | • Share the entry 'State Food and Drug Administration': | | | • View the NEWS results for 'State Food and Drug Administration' (2).
| | | | |
| | | Searchterm 'State Food and Drug Administration' was also found in the following service: | | | | |
| | |
| |
|
From Aurora Imaging Technology, Inc.;
The Aurora® 1.5T Dedicated Breast MRI System with Bilateral SpiralRODEO™ is the first and only FDA approved MRI device designed specifically for breast imaging. The Aurora System, which is already in clinical use at a growing number of leading breast care centers in the US, Europe, got in December 2006 also the approval from the State Food and Drug Administration of the People's Republic of China (SFDA).
'Some of the proprietary and distinguishing features of the Aurora System include: 1) an ellipsoid magnetic shim that provides coverage of both breasts, the chest wall and bilateral axillary lymph nodes; 2) a precision gradient coil with the high linearity required for high resolution spiral reconstruction;; 3) a patient-handling table that provides patient comfort and procedural utility; 4) a fully integrated Interventional System for MRI guided biopsy and localization; and 5) the user-friendly AuroraCADâ„¢ computer-aided image display system designed to improve the accuracy and efficiency of diagnostic interpretations.'
Device Information and Specification
CONFIGURATION
Short bore compact
TE
From 5 ms for RODEO Plus to over 80 ms, 120 ms for T2 sequences
Around 0.02 sec for a 256x256 image, 12.4 sec for a 512 x 512 x 32 multislice set
20 - 36 cm, max. elliptical 36 x 44 cm
POWER REQUIREMENTS
150A/120V-208Y/3 Phase//60 Hz/5 Wire
| | | | • View the DATABASE results for 'Aurora® 1.5T Dedicated Breast MRI System' (2).
| | | • View the NEWS results for 'Aurora® 1.5T Dedicated Breast MRI System' (3).
| | | | Further Reading: | News & More:
|
|
| |
| | | MRI Safety Resources | | | | |
| | | |
| |
|
| | | | • View the DATABASE results for 'Mangafodipir Trisodium' (6).
| | | • View the NEWS results for 'Mangafodipir Trisodium' (1).
| | | | Further Reading: | | Basics:
|
|
News & More:
| |
| |
| | | Searchterm 'State Food and Drug Administration' was also found in the following services: | | | | |
| |
| |
| | 1 - 3 (of 3) Result Pages : [1] |
| |
|
| |
| Look Ups |
| |
|
MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies. | | [last update: 2024-02-26 03:41:00] |
|
|