A bolus is a rapid infusion of high dose contrast agent. Dynamic and accumulation phase imaging can be performed after bolus injection. Since the transit time of the bolus through the tissue is only a few seconds, high temporal resolution imaging can be required to obtain sequential images during the wash in and wash out of the contrast material and, therefore, resolve the first pass of the tracer.
For the same injected dose of contrast agent the injection rate (and, consequently, the total injected volume) modifies the bolus peak profile. Increasing the injection rate produces a sharpening of the peak
(Cmax increase, Tmax decrease, peak length decrease). At a
low injection rate, the first pass presents a plateau form.
Substantial changes in the gadolinium concentrations during signal acquisition induce artifacts. Furthermore, the haemodynamic
parameters ( cardiac output, blood pressure) influence
the bolus profile.
The characteristics of gadolinium agents are favorable in the early bolus
phase, whereas the advantages of large complexes (e.g. blood pool agents) and ultrasmall superparamagnetic iron oxide ( USPIO) are most evident in the distribution phase. | | | | | | • View the DATABASE results for 'Bolus Injection' (9).
| | | | Further Reading: | News & More:
|
|
| |
| | | | | |
| |
|
(MR mammography) Magnetic resonance imaging of the breast is particularly useful in evaluation of newly diagnosed breast cancer, in women whose breast tissue is mammographically very dense and for screening in women with a high lifetime risk of breast cancer because of their family history or genetic disposition.
Breast MRI can be performed on all standard whole body magnets at a field strength of 0.5 T - 1.5 Tesla. Powerful gradient strengths over 15 mT/m will help to improve the balance between spatial resolution, scanning speed, and volume coverage. The use of a dedicated bilateral breast coil is obligatory.
Malignant lesions release angiogenic factors that increase local vessel density and vessel permeability. Breast cancer is detectable due to the strong enhancement in dynamic breast imaging that peaks early (about 1-2 min.) after contrast medium injection. If breast cancer is suspected, a breast biopsy may be necessary to secure the diagnosis. See also Magnetic Resonance Imaging MRI, Biopsy and MR Guided Interventions.
Requirements in breast MRI procedures:
•
Both breasts must be measured without gaps.
•
For the best possible detection of enhancement fat signal should be eliminated either by image subtraction or by
spectrally selective fat saturation.
•
Thin slices are necessary to assure absence of partial
volume effects.
•
Imaging should be performed with a spatial
resolution in plane less than 1 mm.
For Ultrasound Imaging (USI) see Breast Ultrasound at Medical-Ultrasound-Imaging.com.
See also the related poll result: ' MRI will have replaced 50% of x-ray exams by' | | | | | | | | | | | • View the DATABASE results for 'Breast MRI' (13).
| | | • View the NEWS results for 'Breast MRI' (41).
| | | | Further Reading: | | Basics:
|
|
News & More:
| |
Technology advances in breast cancer screenings lead to early diagnosis Friday, 6 October 2023 by ksltv.com | | |
Are synthetic contrast-enhanced breast MRI images as good as the real thing? Friday, 18 November 2022 by healthimaging.com | | |
Abbreviated breast MRI protocols not as cost-effective as promised, new study shows Wednesday, 20 July 2022 by healthimaging.com | | |
Deep learning poised to improve breast cancer imaging Thursday, 24 February 2022 by www.eurekalert.org | | |
Pre-Operative Breast MRI Can Help Identify Patients Likely to Experience Nipple-Sparing Mastectomy Risks Wednesday, 7 April 2021 by www.diagnosticimaging.com | | |
Breast cancer screening recalls: simple MRI measurement could avoid 30% of biopsies Monday, 1 March 2021 by www.eurekalert.org | | |
A Comparison of Methods for High-Spatial-Resolution Diffusion-weighted Imaging in Breast MRI Tuesday, 25 August 2020 by pubs.rsna.org | | |
Pre-Operative Breast MRI Diagnoses More Cancers in Women with DCIS Thursday, 9 July 2020 by www.diagnosticimaging.com | | |
Breast MRI and tumour biology predict axillary lymph node response to neoadjuvant chemotherapy for breast cancer Thursday, 26 December 2019 by cancerimagingjournal.biomedcentral.com | | |
Breast MRI Coding Gets an Overhaul in 2019 Wednesday, 9 January 2019 by www.aapc.com | | |
How accurate are volumetric software programs when compared to breast MRI? Thursday, 27 July 2017 by www.radiologybusiness.com | | |
Additional Breast Cancer Tumors Found on MRI After Mammography May Be Larger, More Aggressive Wednesday, 9 December 2015 by www.oncologynurseadvisor.com | | |
Preoperative MRI May Overdiagnose Contralateral Breast Cancer Wednesday, 2 December 2015 by www.cancertherapyadvisor.com | | |
BI-RADS and breast MRI useful in predicting malignancy Wednesday, 30 May 2012 by www.oncologynurseadvisor.com |
|
| |
| | | Searchterm 'temporal' was also found in the following services: | | | | |
| | |
| |
|
Cine sequences used in cardiovascular MRI are collection of images (usually at the same spatial location) covering of one full period of cardiac cycle or over several periods in order to obtain complete coverage.
The pulse sequence used, is either a standard gradient echo pulse sequence, a segmented data acquisition, a gradient echo EPI sequence or a gradient echo with balanced gradient waveform.
In cardiac gating studies it is possible to assign consecutive lines either to different images, yielding a multiphase sequence with as many images as lines, or the lines are grouped together into segments and assigned to the same image. The overall time to acquire such a segment has to be small compared to the RR-interval of the cardiac cycle, i. e. 50 ms, and hence contains typically 8 to 16 image lines.
This strategy is called segmented data acquisition, and has the advantage of reducing overall imaging time for cardiac images so that they can be acquired within a breath hold, but obviously decreasing the temporal resolution of each individual image.
This method shows dynamic processes, such as the ejection of blood out of the heart into the aorta, by means of fast imaging and displaying the resulting images in a sequential-loop, the impression of a real-time movie is generated. Ejection fractions and stroke volumes calculated from these cine MRI images in different cardiac axes have been shown to be more accurate than any other imaging modality. See also Cardiac Gating. | | | | | | • View the DATABASE results for 'Cine Sequence' (2).