Osvaldo Pino
Thu. 11 Feb.10, 10:47
[Start of: 'echo spacing' 0 Reply]
Category:
Basics and Physics |
echo spacing |
how can I increase echo spacing without modifying the bandwith in a Siemens Trio?
|
| | Reply to this thread (login or register first) | |
Steve Chaloner
Thu. 3 Nov.11, 22:22
[Start of: 'GE FRFSE echo train length' 1 Reply]
Category:
Sequences and Imaging Parameters |
GE FRFSE echo train length |
I've been told that when using FRFSE the ETL should be an odd number. Is this true and if so why? Thanks.
|
| View the whole thread | Reply to this thread (login or register first) | |
|
Philip Lledo
Thu. 22 Oct.09, 08:15
[Start of: 'MRI Techologist' 0 Reply]
Category:
Jobs |
MRI Techologist |
Sir, Presently me working is Saudi Arabia under the Sponsor Ministry of Heath. I have 7 years experiece in the field of my expertise. I handled different types of machine, such as: Siemens Vision 1.5 Tesla Close MRI, Siemens Corcerto 0.2 Tesla Open MRI, Hitachi Aperto 0.4 Tesla Open MRI and Philips Achieva 1.5 Tesla Close MRI. Im holding a two license one from the Philippine Professional Regulation Commission and the other is from Saudi Council for Health Specialties. At the same time,i have been processing my registration for Heath professional Council (HPC)to be credited in the United Kingdom, London.
Many Thanks,
Philip C. Lledo
|
| | Reply to this thread (login or register first) | |
Riccardo Melis
Tue. 24 Sep.24, 03:27
[Start of: 'Bruker Paravision 4.0 Type of Image Reconstruction' 0 Reply]
Category:
Sequences and Imaging Parameters |
Bruker Paravision 4.0 Type of Image Reconstruction |
Hello everyone!
Anyone here using the MRI Bruker Paravision software?
I would need to know with which method (SENSE or GRAPPA) the T2-weighted images are reconstructed (as example by using a Multi Slice Multi Echo sequence)
Thank you in advance!
Riccardo
|
| | Reply to this thread (login or register first) | |
Gina Key
Sat. 27 Jan.24, 09:33
[Reply (1 of 2) to: 'IDEAL sequence help' started by: 'gianluca turcatel' on Mon. 10 Jan.22]
Category:
General |
IDEAL sequence help |
To calculate the Proton Density Fat Fraction (PDFF) from MRI images of the liver acquired using LMS IDEAL (Iterative Decomposition of Water and Fat with Echo Asymmetry and Least Squares Estimation) with optimized low flip angles, you'll typically have multiple image sets corresponding to different echoes. The fat and water signals are separated based on their chemical shift differences. Look for image sets labeled as Water, Fat, or PDFF (Proton Density Fat Fraction). Depending on the software or DICOM tags used, the images may be explicitly labeled, or you may need to review the sequence parameters to determine which set corresponds to fat or water.
|
| View the whole thread | |
| |