Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 




 
MRI Forum
'Gradient'
SEARCH FORUM FOR   
 
Result: Searchterm 'Gradient' found in 38 messages
Result Pages: 1 2 3 4 5 6 7 [8] 
More Results: Database  (316)  News Service  (6)  Resources  (7)  
Forum Overview
 bottom
Nancy Dudek

Fri. 26 Aug.05,
00:25

[Start of:
'3T imaging parameters'
2 Replies]


 
  Category: 
Sequences and Imaging Parameters

 
3T imaging parameters
Hi
Am looking for the ranges of acceptable TR and TE's for standard spin echo and gradient echo sequences on a 3T.
Does anyone know these or tell me where I can find this info?
 View the whole threadReply to this thread
(login or register first)
tina muthana

Thu. 14 Apr.05,
22:44

[Start of:
'diffusion MRi'
1 Reply]


 
  Category: 
Basics and Physics

 
diffusion MRi
Hi
My name is Tina and I am currently studying Diffusion weighted MRI. I was wondering if anyone could elaborate on the effect of introducing a slice selection gradient along with the diffusion gradient on the signal attenuation. Also if there are any sites that could explain it, I would appreciate the information.
Thank you.
-TIna
 View the whole threadReply to this thread
(login or register first)
Schmidt Marga

Sat. 17 Apr.04,
20:41

[Reply (1 of 2) to:
'Moire fringing'
started by: 'Kelly Wimpey'
on Tue. 6 Apr.04]


 
  Category: 
Artifacts

 
Moire fringing
Moire fringes are typical for gradient echo sequences, especially balanced sequences like for example true fisp, bFFE. The reasons are interferences and field inhomogeneities. High order shimming (volume shimming), a more suitable coil, a smaller bandwidth, and scanning not in the edges of the magnetic field will avoid or reduce this artifact. Also parallel imaging techniques can have a positive influence. If this artifact appears, also by using other sequences, a new field adjustment can be necessary (service).
Hope this will help.
 View the whole thread

Result Pages : 1 2 3 4 5 6 7 [8] 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]