New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 




 
MRI Forum
'Sequences'
SEARCH FORUM FOR   
 
Result: Searchterm 'Sequences' found in 59 messages
Result Pages: 1 2 3 4 5 6 7 8 9 10 [11] 12 
More Results: Database  (188)  News Service  (6)  Resources  (8)  
Forum Overview
 bottom
Reader Mail

Mon. 30 Oct.06,
16:25

[Reply (1 of 2) to:
'interleaved slices and mean intensity difference in adjacent slices'
started by: 'Reader Mail'
on Wed. 4 Oct.06]


 
  Category: 
General

 
interleaved slices and mean intensity difference in adjacent slices
With interleaved slice acquisition for example in each TR first the odd slices, and then the even slices are acquired. Differences in signal intensity may occur by changes between these acquisitions (like movement), especially with a long TR. In particular, for fMRI sequences with interleaved slice acquisition a slice time correction is recommended to get accurate measurements.
However, I think "large" signal intensity differences with interleaved slices (except fMRI) are rarely seen with usual sequences and sufficient processing (interpolation) algorithms.
 View the whole thread
Giorgos Menikou

Sat. 27 May.06,
07:16

[Start of:
'GE Signa Excite 1.5 T HD spectroscopy fine shimming'
0 Reply]


 
  Category: 
Spectroscopy

 
GE Signa Excite 1.5 T HD spectroscopy fine shimming
Can anyone please give directions for how to use the SpectroScan Tool in spectroscopic sequences.
It is necessary to optimise the shimming in spectroscopy in order to get well defined sharp peaks in the metabolites spectrum.
Reply to this thread
(login or register first)
Angel Lara

Fri. 20 Jan.06,
14:33

[Reply (2 of 3) to:
'siemens impact expert'
started by: 'Angel Lara'
on Thu. 5 Jan.06]


 
  Category: 
Sequences and Imaging Parameters

 
siemens impact expert
Thank You,

Please excuse me But how should the silicon scout look?
What other sequences should I run to complete the protocol, and will the other sequences be affected by the scanner tunning to silicone instead of water?
 View the whole thread
terry santos

Thu. 5 Jan.06,
23:54

[Reply (1 of 3) to:
'siemens impact expert'
started by: 'Angel Lara'
on Thu. 5 Jan.06]


 
  Category: 
Sequences and Imaging Parameters

 
siemens impact expert
shim system as normal

Then there should be a scout_silicone protocol.
tirm11_wss60b130.wlc TR 1530

If scout shows sillicone then use
tirm11_wss60b130.wlc TR 8568 4 mm cuts


If scout shows water only then use
tirm11_ss60b130.wlc TR 8568 4 mm cuts

The scout is :22 sec

The other sequences are 3:17
 View the whole thread
Nancy Dudek

Fri. 26 Aug.05,
00:25

[Start of:
'3T imaging parameters'
2 Replies]


 
  Category: 
Sequences and Imaging Parameters

 
3T imaging parameters
Hi
Am looking for the ranges of acceptable TR and TE's for standard spin echo and gradient echo sequences on a 3T.
Does anyone know these or tell me where I can find this info?
 View the whole threadReply to this thread
(login or register first)

Result Pages : 1 2 3 4 5 6 7 8 9 10 [11] 12 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]