Alyssa Cash
Wed. 22 Apr.20, 07:45
[Start of: 'ACR QC' 0 Reply]
Category:
General |
ACR QC |
Can anyone tell me where to find the center frequency and TX GAIN for my daily QC on a Siemens Espree???
|
| | Reply to this thread (login or register first) | |
Albert Yen
Wed. 5 Feb.20, 02:54
[Reply (1 of 2) to: 'MRI-PDFF' started by: 'Imran Chunawala' on Sun. 14 Jul.19]
Category:
General |
MRI-PDFF |
Hi, You may start with checking the MRI candidate sites whether their MRI is equipped with following package: IDEAL IQ for GE MRI scanner, mDIXON-Quant for Philips MRI scanner, LiverLab for Siemens MRI scanner. This shall shall exclude some candidates and save a lot efforts. Certainly there will be other concerns if it's a multi-center study. This article may help: https://www.birpublications.org/doi/pdf/10.1259/bjr.20170378
|
| View the whole thread | | |
Haider Ali
Thu. 15 Sep.16, 02:26
[Start of: 'Toshiba Vantage Titan 3T' 0 Reply]
Category:
Equipment |
Toshiba Vantage Titan 3T |
While planning vertebral discs for axial cuts is there any way to align the slices perpendicularly on coronal plane? Currently I have to manually align them on the vertebral column which is tedious and sometimes erroneous.
I have worked on Siemens Avanto and there is option to select the slice to align perpendicular so that I only have to pay attention to one plane while in Toshiba the task is a bit more complicated. Though there is an option of aligning all slices perpendicularly but it does not work or may be I am doing something wrong.
|
| | Reply to this thread (login or register first) | |
Pontus Zaar
Mon. 23 May.16, 20:04
[Start of: 'Tirm dark fluid, fat signal.' 0 Reply]
Category:
Basics and Physics |
Tirm dark fluid, fat signal. |
Hi!
On our 3 T siemens machine the protocol tirm dark fluid is often used in neuro.
My question is, why does fat have low signal? Isn't supposed to be only fluid supressed?
Thanks in advance!
/Pontus
|
| | Reply to this thread (login or register first) | |
stephen cody
Fri. 13 Feb.15, 19:42
[Reply (22 of 26) to: 'MRI Technologists Jobs in Saudi Arabia' started by: 'Mosta Mosta' on Tue. 3 Mar.09]
Category:
Jobs |
MRI Technologists Jobs in Saudi Arabia |
Hello I am interested in your mri position please review my resume and let me know if I can be of service. Thank You
Stephen Cody
Stephen M. Cody, ARRT, R, MR
324 Catalpa St. #115
San Mateo CA. 94401
(832) 816-8514
smcody@hotmail.com
Education
Academy of Health Sciences, Fort Sam Houston, San Antonio, Texas
Radiology Technologist Program - September 1977
Summary of qualifications
More than 25 years of radiology experience; 15 years training others
Registered by the ARRT
Fully experienced with diagnostic techniques using CT and MRI
Organized, efficient and a problem-solver
Work experience
San Francisco General Hospital 3/11-present
Optimizing protocols, training staff and doing cardiac MRI.
National Institutes of Health 3/09-2/11
oLead MRI technologist. Trained staff on Siemens MRI scanners, performed cardiac MRI and spectroscopy on the heart and liver. Worked with physicists and radiologists on various research protocols.
Phillips Medical 1/08-2/09
Verification and validation testing on the Phillips iSite Pacs
Contractor 9/04-08
Completed several MRI assignments across the United States, listed below:
Piedmont Medical Center, Rock Hill, S.C.
UC-Davis Hospital, Sacramento, Calif.
Brazosport Memorial Hospital, Lake Jackson, Texas
Bay Medical Center, Panama City, Fla.
Memorial Hermann Hospital System, Houston, Texas
Presbyterian Hospital, Dallas, Texas
Oregon Health Sciences Hospital, Portland, Ore.
Neurology Consultants of Dallas 9/03-3/04
Facilitated startup and operation of the neurology group's MRI services.
Southwest Diagnostic Imaging Center 3/03-12/-03
(Concurrent with neurology center)
Med Relief Staffing 1/00-2/03
National University Hospital of Singapore 2/96-12/99
MRI technologist, responsible for training staff and managing MRI operations.
Jacinto MRI Center 8/93-1/96
Chief technician of this Houston, Texas, center, which initially started with MRI and expanded to a full-range outpatient center. Responsibilities included training staff in CT and MRI; broad technical direction; marketing and RSO.
Spectrum Imaging 4/90-7/92
Manager for this Houston, Texas, center. Was responsible for marketing, business development, technical operations and equipment purchases.
Houston Imaging Centers 1/89-3/90
MRI supervisor, standardizing centers' protocols, including a Q.A. program. Trained several new techs.
The Methodist Hospital 2/84-10/88
Angio, CT technician. Performed and trained in various angio and CT procedures. MRI training began in my last year of employment.
Equipment:
CT: GE 9800, Quick Advantage, Cytech, Siemens DRH
MRI: Technicare.6 Phonar .3 GE Cigna 4X and 5X 9X 14X 16X, 1.5 and 3T; Toshiba Opart; Hitachi 7000 and Aris; Phillips 1.5 NT and T5; Elscint .5; Siemens 1.5 Vision and .2 Open Viva Magnets; Siemens 1.5 Symphony Maestro Class, Avanto and Espirit Verio 3T; Phillips 1.5 Intera 3T Achieva
|
| View the whole thread | | |
| |