Result: Searchterm 'Signa'
found in 78 messages |
Result Pages: [1] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 |
More Results: Database (382) News Service (60) Resources (16) |
|
Costel Chiru
Thu. 1 Dec.16, 21:13
[Start of: 'GE Signa Explorer' 0 Reply]
Category:
General |
GE Signa Explorer |
Did anyone know how many coils elements could be simultaneously connected to 16 ch GE Signa Explorer?rnThanks!
|
| | Reply to this thread (login or register first) | |
Pontus Zaar
Mon. 23 May.16, 20:04
[Start of: 'Tirm dark fluid, fat signal.' 0 Reply]
Category:
Basics and Physics |
Tirm dark fluid, fat signal. |
Hi!
On our 3 T siemens machine the protocol tirm dark fluid is often used in neuro.
My question is, why does fat have low signal? Isn't supposed to be only fluid supressed?
Thanks in advance!
/Pontus
|
| | Reply to this thread (login or register first) | |
|
Niels Janssen
Tue. 6 May.14, 11:24
[Start of: 'GE signa excite 3T - clustered volume acquisition' 0 Reply]
Category:
Funktional MRI |
GE signa excite 3T - clustered volume acquisition |
I am wondering if anyone has experience with so called 'clustered volume acquisition' on a GE signa excite 3T. Clustered volume acquisition (or sparse acquisition) means that you acquire images within the first 1000 ms of a 2000 ms TR, for example (Edmister et al., 1999, Human Brain Mapping). This method is useful because the machine will stop producing scanning noise in the final 1000 ms of the TR, which can then be used for recording speech inside the scanner (in fmri applications).
I am asking whether 1) this sequence can be programmed from the parameters menu on the scanner console, or 2) whether it requires compilation of a new pulse sequence.
|
| | Reply to this thread (login or register first) | |
Reader Mail
Tue. 25 Sep.07, 14:56
[Start of: 'GE Signa Contour field' 0 Reply]
Category:
Devices, Scanner, Machines |
GE Signa Contour field |
HI,
I NEED THE LINES OF FIELD FOR THIS GE SIGNA CONTOUR: 0,5 T SIGNA/MAX W/SAV
CAN YOU HELP ME?
THANKS
|
| | Reply to this thread (login or register first) | |
Gonzalo Sanchez Benavides
Tue. 5 Jun.07, 07:53
[Start of: 'DTI 25 directions on GE signa excite 1.5' 4 Replies]
Category:
Sequences and Imaging Parameters |
DTI 25 directions on GE signa excite 1.5 |
Hello,
I need some help with the DTI 25 gradient directions on GE signa excite.
I'm a neuropsychology researcher and i receive some data with this protocol, but the technician cannot tell me the matrix that i need to process it. It's somthing like this:
26
0 0 0
1 0 1
...
If anybody can help me i would be very grateful.
Thanks
|
| View the whole thread | Reply to this thread (login or register first) |
| |
| Result Pages : [1] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | |
|
| |