Muhammad Arshad

Sat. 28 Aug.10,
12:16

[Reply (14 of 26) to:
'MRI Technologists Jobs in Saudi Arabia'
started by: 'Mosta Mosta'
on Tue. 3 Mar.09]


 
  Category: 
Jobs

 
MRI Technologists Jobs in Saudi Arabia
I am MRI and CT Technologist in King Abdullah Medical Makkah. I am working on Siemens MRI Magnetom Espree and Somatom 64 slice ct.
 View the whole thread
A Marsh

Mon. 5 Oct.09,
16:53

[Start of:
'MRA BRAIN'
0 Reply]


 
  Category: 
Applications and Examinations

 
MRA BRAIN
Should block of slices angled or not angled on the scout.
Reply to this thread
(login or register first)
waseem zafar

Thu. 3 Sep.09,
11:09

[Start of:
'MRI TECHNOLOGIST'
0 Reply]


 
  Category: 
Jobs

 
MRI TECHNOLOGIST
i am medical imaging technologist,i have passed BSc(HONS) Medical imaging technology in july 2007 from university of health sciences lahore.i have great experience of MRI(1.5T PHILIPS Magnetom,1.5T Siemens Avanto,Hitachi0.35T.ICAN PERFORM ALL TYPES OF SCANNING OF MRI INCLUDINGMRA,MRV,PERFUSION,DIFFUSION etc,
ihave also good experience of CT 64 SLICES TOSHIBA AQUILION,I CAN PERFORM ALL PERIPHERAL ANGIO,CARDIAC ANGIO,BIPHASIC AND OTHER CT PROCEDURES,I HAVE GREAT EXPERIENCE OF POSTPROCESSINF ON WORKSTATION OR VITREA,I CAN MAKE ALL 3D IMAGES ON VITREA.I AHVE EXPERINENCE OF NUCLEAR MEDICINE,AND FUJI CR SYSTEM,
I WANT TO WORK AT SAUDI ARABIA SO A I M LOOKING FOR THE JOB
Reply to this thread
(login or register first)
Matthijs Lipperts

Wed. 7 Jan.09,
11:05

[Start of:
'SPAIR movement artefact'
0 Reply]


 
  Category: 
Artifacts

 
SPAIR movement artefact
Dear all,
When scanning wrists in our Avanto MR always the penultimate slice in the transversal series shows a movement artefact. This happens with all patients and always the penultimate slice. We found out that using regular fat saturation this does not occur, with SPAIR (which is preferable because of the frequent susceptibility artefacts in arms/wrists) however it happens all the time. The simple solution for our radiology staff is to use normal fat saturation instead of SPAIR, however we are intriged by this problem and were hoping that anyone also experienced this problem and maybe found an explanation.
Because it happens in only 1 slice we are suspecting some kind of interference of the slice selection pulse with the SPAIR pre-pulses.
Any input is appreciated,
thanks in advance, Matthijs
Reply to this thread
(login or register first)
Hugo Robalo

Thu. 3 Apr.08,
16:22

[Reply (2 of 4) to:
'MRI Bandwidth and turbo factor relation ?'
started by: 'young bong we'
on Thu. 20 Mar.08]


 
  Category: 
Basics and Physics

 
MRI Bandwidth and turbo factor relation ?
A higher BW will increase the noise, minimum FoV, slices per TR and will decrease the minimum TE, SNR and echo spacing.
 View the whole thread

Result Pages : 1 2 3 4 5 [6] 7 8 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]