Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 




 
MRI Forum
'T1 Time'
SEARCH FORUM FOR   
 
Result: Searchterm 'T1 Time' found in 3 messages
Result Pages: [1] 
More Results: Database  (15)  News Service  (3)  
Forum Overview
 bottom
Adana Osco Barras

Tue. 3 Jan.12,
21:09

[Reply (1 of 2) to:
'Hyperintense blood vessels in SE'
started by: 'Peruvumba Jayakumar'
on Thu. 29 Dec.11]


 
  Category: 
Sequences and Imaging Parameters

 
Hyperintense blood vessels in SE
Prolonged T1 relaxation times, decreased T1 tissue contrast, and increased susceptibility rnare typical effects at high field MRI.rnDue to the longer T1 times at 3T, the signal rnintensity inside the vessels is preserved even in smaller vessels. Try TR 700, TE 10.rnInversion recovery sequences are very well suited for optimal gray to white matter contrast, but enhancement after administration of gadolinium may not be visible.
 View the whole thread
Renate Bloemer

Mon. 13 Nov.06,
19:29

[Reply (1 of 2) to:
'T1 FAT SAT PRE AND POS GADO'
started by: 'CLAUDIO RIBERTI'
on Tue. 24 Oct.06]


 
  Category: 
Contrast Agents

 
T1 FAT SAT PRE AND POS GADO
The contrast agent causes this difference. Contrast agents reduce the T1 time in tissues where they have accumulated depending on blood flow and vascular permeability. Caused by this, tissues after an application of contrast agents will differ in shortening of the T1 time, and the same imaging parameters result in other image appearance.
Some helpful links for musculoskeletal imaging and Fat Sat:
http://www.moffitt.org/moffittapps/ccj/v8n3/pdf/221.pdf
http://www.medical.siemens.com/siemens/en_US/gg_mr_FBAs/files/MRI_Hot_Topics/MRI_HotTopics_Skinny_on_FatSat_engl.pdf

Hope this helps
 
 

Renate Bloemer
 View the whole thread
Susan Angelico

Thu. 15 Sep.05,
20:07

[Reply (1 of 3) to:
'3T imaging parameters'
started by: 'Nancy Dudek'
on Fri. 26 Aug.05]


 
  Category: 
Sequences and Imaging Parameters

 
3T imaging parameters
At 3T the T1 time is longer (so the TR should also be longer) and the T2 time is shorter (TE can be shorter). However, when we got a 3T machine we tested different TR and TE's and found out that in practice the useful range don't has a big difference from that of a 1.5T MR system.
The contrast looks a bit different - that's normal.
In addition, ask the manufacturer.
There are a lot of other parameters that affect the contrast in 3T.

Hope this will help
 View the whole thread

Result Pages : [1] 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]