'T1/T2 relaxation time charts'
1 Reply]


 
  Category: 
General

 
T1/T2 relaxation time charts
Does anyone have a reliable T1/T2 relaxation chart for the different tissue types? Or could you point me in the direction of a website that has them listed? I haven't been able to find a formula. Thank you.
 View the whole threadReply to this thread
(login or register first)
mm jj

Thu. 31 Aug.17,
04:30

[Start of:
'flipping'
0 Reply]


 
  Category: 
General

 
flipping
hi
cam we flip net magnetisition vector more than 180? if so,what happens?
after flipping 360 degree,is there any relaxation?
360 pulse makes spins back to initial state?
thanks in advance.
Reply to this thread
(login or register first)
Eric Gonzalez

Wed. 10 Oct.12,
20:06

[Reply (1 of 2) to:
'Brain T2FS postcontrast'
started by: 'kaisa bente'
on Thu. 27 Jan.11]


 
  Category: 
Applications and Examinations

 
Brain T2FS postcontrast
Gadolinium relaxation times are too short for T2 weighted imaging, so T2 weighted is not tipically performed after contrast (unless used as a delay to give contrast time to peak before T1 FS is obtained).

Also I have never worked at any facility that uses T2 fat sat imaging on the brain. Not a whole lot of fat in the brain region!

FLAIR imaging is the norm...but I could stand corrected.
 View the whole thread
Adana Osco Barras

Tue. 3 Jan.12,
21:09

[Reply (1 of 2) to:
'Hyperintense blood vessels in SE'
started by: 'Peruvumba Jayakumar'
on Thu. 29 Dec.11]


 
  Category: 
Sequences and Imaging Parameters

 
Hyperintense blood vessels in SE
Prolonged T1 relaxation times, decreased T1 tissue contrast, and increased susceptibility rnare typical effects at high field MRI.rnDue to the longer T1 times at 3T, the signal rnintensity inside the vessels is preserved even in smaller vessels. Try TR 700, TE 10.rnInversion recovery sequences are very well suited for optimal gray to white matter contrast, but enhancement after administration of gadolinium may not be visible.
 View the whole thread
John Jackson

Fri. 12 Sep.08,
08:48

[Reply (1 of 3) to:
'Regarding recovery and decay [basic phycisc]'
started by: 'harry sanders'
on Sat. 7 Jun.08]


 
  Category: 
Basics and Physics

 
Regarding recovery and decay [basic phycisc]
Hi,

I'm not so sure but I think because different physical process are being involved. Longitudal relaxation has got something to do with energy exchange to the environment. Transverse relation occurs because of spin dephasing (magnetic inhomogenity.)

John
 View the whole thread

Result Pages : [1] 2 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]