 bottom
Mike Parks

Fri. 6 Apr.07,
18:53

[Start of:
'Need Help'
0 Reply]


 
  Category: 
Applications and Examinations

 
Need Help
I had an MRI yesterday and I have alot of metal in my neck due to extensive surgery such as anterior fusion from c4 to c7. Yesterdays results indicate I have atrophy of the spinal cord from C4-5 to C7 with a thin cord and high signal compatible with myelomalacia. Herniation of C3-$ that compresses the spinal cord. Central protrusion of the C2-3 and C7-T1 discs. My question is. My neck burns as if on fire inside. Is this something that will go away? I have and do have severe pain 24/7 but I've never had this kind of pain. If possible please email me at oceansmove07@aol.com if you know what's happening. Thank you for any help you may have and I wish everyone a lighter today, a brighter tomorrow and a future filled with joy and happiness.
Reply to this thread
(login or register first)
Johan J

Tue. 20 Mar.07,
16:22

[Reply (1 of 2) to:
'MRI Claustrophobia Interview Request'
started by: 'Sion Rogers'
on Wed. 21 Feb.07]


 
  Category: 
Safety

 
MRI Claustrophobia Interview Request
Roger,

Claustrofobia is difficult topic, real claustrofobic patient won't enter the room...and thus won't experience MR.

Interesting question is how the environment surounding the actual MR, influences this behaviour (Ambient Experience). Also consider looking at High Field Open MR systems (1.0T).

Cheers
 View the whole thread
Johan J

Tue. 20 Mar.07,
15:55

[Reply (1 of 2) to:
'fluid PD vs T2 weighting'
started by: 'Reader Mail'
on Tue. 6 Mar.07]


 
  Category: 
Sequences and Imaging Parameters

 
fluid PD vs T2 weighting
The truth is basicley that different tissues have different relaxation times, the signal of fluid last longer than fat in a T2, so it appears bright.

But also with a "short" TE of 30ms you can already achieve a high signal of fluid, but this is highley dependend of the TR. A long TR - 5000ms - will give you a high signal of fluid. But scantimes won't be acceptable...
 View the whole thread
Rob van den Dobbelsteen

Sat. 10 Mar.07,
16:33

[Start of:
'What´s this in L3?'
1 Reply]


 
  Category: 
Applications and Examinations

 
What´s this in L3?
I´m a Dutch Physiotherapist and not trained in reading MRI images.
Yesterday my last client brought a CD with MRI-images on his first visit. He experiences a lot of lumbar pain, takes lots of painkillers and had a HNP operation earlier.

There is something strange about L3. Can you tell me what it is?

The doctor only told him there was no reason to think he had neurological problems but never mentioned this.

Pictures can be seen here:
http://www.fysioforum.nl/e107_plugins/forum/forum_viewtopic.php?957
 View the whole threadReply to this thread
(login or register first)
Reader Mail

Tue. 6 Mar.07,
22:48

[Start of:
'fluid PD vs T2 weighting'
1 Reply]


 
  Category: 
Sequences and Imaging Parameters

 
fluid PD vs T2 weighting
Can anyone explain me, why - considering SE sequences with the same TR - fluid in a PD weighting (short TE) should have less signal than in a T2 weighting (long TE)? eg:
Fig 10, p 1397; radiographics resident tutorial: contrast mechanisms in spin echo MR imaging; Radiographics 1994; 14; pp 1389-1404

I would expect that the signal intensity of any tissue (regardless of it Proton density of T2-relaxation time) should decrease with increasing echo time.

Thank you
 View the whole threadReply to this thread
(login or register first)

Result Pages : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 [68] 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]