Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Omniscan®' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Omniscan®' found in 1 term [] and 4 definitions []
1 - 5 (of 5)     
Result Pages : [1]
MRI Resources 
Collections - Spectroscopy - Devices - Anatomy - Implant and Prosthesis pool - Case Studies
 
Omniscan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Omniscan® is a nonionic chelate complex with low osmolality used as a paramagnetic MRI contrast agent. The efficacy of Omniscan® is similar to that of Gd-DTPA. Omniscan® is given intravenously to enhance images of intracranial and spinal lesions where there is abnormal vascularity or an abnormal blood brain barrier. The complex does not cross an intact blood brain barrier so Omniscan® only accumulates in lesions such as neoplasm's and abscesses.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Gadodiamide, and Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
Gadodiamide, Gd-DTPA-BMA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.9, r2=4.3, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
798 mosm/kgH2O
CONCENTRATION
287 mg/mL,0.5 mol/L
DOSAGE
0.1-0.2 mmol/kg / 0.2-0.4 ml/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 10 mL, 15 mL and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Omniscan®
for sale
EU
Omniscan®
suspended
Australia
Omniscan®
for sale
spacer
 
• Share the entry 'Omniscan®':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Omniscan Pharmacokinetics
  News & More:
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
MRI Resources 
Developers - - Distributors - Shoulder MRI - Resources - Education pool
 
GE HealthcareMRI Resource Directory:
 - Manufacturers -
 
www.gehealthcare.com GE Healthcare is the result of the merger between GE Medical and Amersham Health in Nov. 2004, after GE acquired Amersham Health for 9.5 billion in Oct. 2003. Jeffrey R. Immelt, Chairman of the Board and Chief Executive of General Electric, said, 'Amersham's diagnostic pharmaceutical and life sciences business will add new, high growth platforms to GE Medical's diagnostic imaging, services and healthcare information technology businesses'. GE Healthcare, a UK company, is a unit of General Electric (NYSE: GE). GE Healthcare is a global leader in medical imaging, diagnostic imaging contrast agents, interventional procedures, healthcare services, and information technology. For more than 100 years, health care providers have relied on GE Medical Systems, now GE Healthcare, for high quality medical technology and productivity solutions. GE Healthcare, headquartered now at formerly seat of Amersham Health in Great Britain, operates facilities around the world. Global Operations include organizations on the Americas, Europe, and Asia, including India, Japan, Korea China, Thailand and Vietnam.

MRI Scanners:

MRI Contrast Agents:
•
•
Contact Information
spacer

• View the DATABASE results for 'GE Healthcare' (23).Open this link in a new window


• View the NEWS results for 'GE Healthcare' (26).Open this link in a new window.
 
Further Reading:
  Basics:
GE Medical's new name: GE Healthcare
Friday, 6 February 2004   by milwaukee.bizjournals.com    
  News & More:
GE HealthCare introduces new MRI agent Pixxoscan
Friday, 28 April 2023   by www.medicaldevice-network.com    
GE Healthcare Names New 3.0T MRI System for Today's Healthcare Heroes
Monday, 13 December 2021   by www.itnonline.com    
GE Healthcare announces FDA approval of macrocyclic MRI contrast agent Clariscan
Monday, 4 November 2019   by www.itnonline.com    
GE Healthcare expands MRI contrast media product range in Europe with launch of macrocyclic agent ClariscanTM
Wednesday, 1 March 2017   by www.businesswire.com    
A*STAR & GE Healthcare Collaborate On Med Tech
Monday, 22 December 2014   by www.asianscientist.com    
MRI Resources 
Calculation - Spine MRI - Libraries - Intraoperative MRI - Mass Spectrometry - Supplies
 
GadoliniumForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(Gd) Gadolinium is a Lanthanide element that is paramagnetic in its trivalent state.
This paramagnetic substance is used for MR imaging because of the effect of strongly decreasing the T1 relaxation times of the tissues to which gadolinium has access. When injected during magnetic resonance imaging, gadolinium will tend to change signal intensities by shortening the T1 time in its surroundings.
The relaxivity of gadolinium is an important measure of its efficacy, which is dependent on the chemical properties of the complex. The gadolinium ion cannot be used in its chloride, sulfate, or acetate forms because of poor tolerance and low solubility in water in the neutral pH range. Although toxic by itself, gadolinium can be given safely in a chelated form such as DTPA, that still retains much of its strong effect on relaxation times (relaxivity).

See also Dotarem®, Gadovist®, MultiHance®, Omniscan®, OptiMARK®, and Contrast Agents, the info sheet gives an overview and more in-dept information about different types of MRI contrast agents.
 
Images, Movies, Sliders:
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Gadolinium' (66).Open this link in a new window


• View the NEWS results for 'Gadolinium' (17).Open this link in a new window.
 
Further Reading:
  Basics:
DNA-SEEKING GADOLINIUM COMPLEXES FOR NEUTRON CAPTURE THERAPY (NCT) (.pdf)
A LANTHANIDE LANTHOLOGY(.pdf)
   by www.phy.davidson.edu    
Gadolinium-Based Agents Safe for MRI Use
Monday, 18 April 2011   by www.renalandurologynews.com    
  News & More:
Stable Spherical Lanthanide Cluster for Magnetic Resonance Imaging Assembly
Wednesday, 26 April 2023   by www.miragenews.com    
Artificial Intelligence Processes Provide Solutions to Gadolinium Retention Concerns
Thursday, 30 January 2020   by www.itnonline.com    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
Contrast MRIs cause claims, concern, over residual metal in brain
Tuesday, 8 December 2015   by www.afr.com    
Contrast agent linked with brain abnormalities on MRI
Tuesday, 17 December 2013   by www.sciencecodex.com    
FDA Approves First Macrocyclic and Ionic Gadolinium-Contrast Agent for MRI
Friday, 22 March 2013   by www.itnonline.com    
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Gadolinium oxide nanoparticles enhance MRI contrast
Thursday, 29 September 2011   by nanotechweb.org    
MRI Resources 
Artifacts - Stent - Guidance - - Coils - Mass Spectrometry
 
Nonionic Intravenous Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Radiographic low-osmolar nonionic contrast agents have less side effects and fewer nephrotoxicity than ionic, high-osmolar agents. Gadolinium-based MRI contrast agents have a different formulation from iodinated X-ray contrast media, and there is no known cross sensitivity between these two types of contrast agents. Intravenous MRI contrast agents, specifically the gadolinium chelates have a high safety and lack of nephrotoxicity compared with X-ray contrast media.
The used gadolinium chelates differ in following properties: linear (e.g., gadodiamide and gadoversetamide have nonionic linear structures) vs. macrocyclic cores, and ionic vs. nonionic types. The nonionic molecules have lower osmolality and viscosity, which increase digestibility at greater concentrations, and make faster bolus injections conceivable. The macrocyclic molecules (e.g., gadoteridol has a nonionic macrocyclic ring structure) are more stable and show fewer tendencies to dissociate free Gd.

See also ProHance®, Omniscan®, OptiMARK®, Ionic Intravenous Contrast Agents.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
spacer

• View the DATABASE results for 'Nonionic Intravenous Contrast Agents' (4).Open this link in a new window

 
Further Reading:
  News & More:
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
   by arpa.allenpress.com    
MRI Resources 
Manufacturers - Mobile MRI - Functional MRI - General - Health - Portals
 
Paramagnetic Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Magnetic relaxation in tissues can be enhanced using contrast agents. The most commonly used for MRI are the paramagnetic contrast agents, which have their strongest effect on the T1, by increasing T1 signal intensity in tissues where they have accumulated.
MRI collects signal from the water protons, but the presence of these contrast agents enhances the relaxation of water protons in their vicinity. Paramagnetic contrast agents contain magnetic centers that create magnetic fields approximately one thousand times stronger than those corresponding to water protons. These magnetic centers interact with water protons in exactly the same way as the neighboring protons, but with much stronger magnetic fields, and therefore, have a much greater impact on relaxation rates, particularly on T1. In MRI, contrast agents are routinely injected intravenously to help identify areas of hypervascularity, as in malignant tumors.

See also Contrast Agents, Gadovist®, MultiHance®, Omniscan®, OptiMARK®.

See also the related poll result: 'The development of contrast agents in MRI is'
 
Images, Movies, Sliders:
 MRI Upper Abdomen T1 with Contrast  Open this link in a new window
    
 MRI Orbita T1  Open this link in a new window
 MRI Orbita T1 with Contrast  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'Paramagnetic Contrast Agents' (22).Open this link in a new window


• View the NEWS results for 'Paramagnetic Contrast Agents' (1).Open this link in a new window.
 
Further Reading:
  Basics:
LEARNING CENTER FOR PARAMAGNETISM
2003   by www.naturesalternatives.com    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
Contrast Agents in Magnetic Resonance Imaging
1997
  News & More:
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
RSNA Statement on Gadolinium-Based MR Contrast Agents
Thursday, 1 February 2018   by www.rsna.org    
Contrast MRIs cause claims, concern, over residual metal in brain
Tuesday, 8 December 2015   by www.afr.com    
MRI Resources 
Diffusion Weighted Imaging - MRI Centers - Contrast Agents - Image Quality - Fluorescence - IR
 
     1 - 5 (of 5)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]