Please note that there are different common names for this artifact.
HELP
Fast scan techniques
Patient movement during the scans are often an imaging problem. Artifacts from patient movement are widely varied due to a dependence when during k-space filling the motion occurs. When the patient moving causes only in the last few seconds of the scan at that time the outside edges of K-space were being filled, and as a result the artifact does not overly affect the image (there are only fine lines).
Image Guidance
| | | | | Further Reading: | News & More:
|
|
| | | |
|
| |
|
Artirem®, the arthrography-specific contrast agent for MRI is a dilute form of Dotarem® with a less concentration of Gd (1:200).
Artirem® has to be injected directly into the joints for better visualization and delimitation, of the ligament and tendon structures in particular.
Drug Information and Specification
T1, Predominantly positive enhancement
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
CONCENTRATION
0,0025 mmol/ml
PREPARATION
Finished product
DEVELOPMENT STAGE
For sale
PRESENTATION
Pre-filled syringes of 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT STAGE
DISTRIBUTOR
France, Switzerland
Artirem®
for sale
| | | | • View the DATABASE results for 'Artirem®' (4).
| | | | Further Reading: | News & More:
|
|
| | | | | | |
|
| |
|
Developed by GE Lunar; the ARTOSCAN™-M is designed specifically for in-office musculoskeletal imaging. ARTOSCAN-M's compact, modular design allows placing within a clinical environment, bringing MRI to the patient. Patients remain outside the magnet at all times during the examinations, enabling constant patient-technologist contact. ARTOSCAN-M requires no special RF room, magnetic shielding, special power supply or air conditioning.
The C-SCAN™ (also known as Artoscan C) is developed from the ARTOSCAN™ - M, with a new computer platform.
Device Information and Specification
CLINICAL APPLICATION
Dedicated extremity
SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
SLICE THICKNESS
2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm
4,096 gray lvls, 256 lvls in 3D
POWER REQUIREMENTS
100/110/200/220/230/240V
| | | | • View the DATABASE results for 'ARTOSCAN™ - M' (3).
| | | | | | |
|
| |
| The collection of more data points on one side of
the k-space origin than on the other. With fewer k-space data points prior
to the center ( echo) a shorter echo time can be attained. Asymmetric
acquisition in any phase encoding direction followed by partial-Fourier
reconstruction leads to a reduction in imaging time. | | | | • View the DATABASE results for 'Asymmetric Sampling' (2).
| | | | | | |
|
| |
| | | | | • View the DATABASE results for 'Asymmetrical Echoes' (2).
| | | | | | | | | |
| | |
|
| |