Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 MRI Database 
SEARCH FOR    
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
previous     46 - 50 (of 98)     next 
Fa-Fa   Fa-Fa   Fa-Fa   Fa-Fa   Fa-Fe   Fe-Fe   Fe-Fe   Fe-Fe   Fe-Fi   Fi-Fi     Fi-Fi   Fi-Fl   FL-Fl   Fl-Fl   Fl-Fl   Fo-Fo   FO-Fr   Fr-Fr   Fr-Fu   Fu-Fu   
MRI Resources 
Image Quality - Lung Imaging - General - Implant and Prosthesis - Distributors - MRI Accidents
 
Field Echo with Echo Time set for Water and Fat Signals in PhaseInfoSheet: - Sequences -
Intro, Overview, 
Types of, 
etc.
 
spacer
Field Effect Transistor
 
(FET) Preamplifiers with high input impedance may be used with surface coils. Such devices typically use a field effect transistor as their input stage.
spacer

• View the DATABASE results for 'Field Effect Transistor' (2).Open this link in a new window

MRI Resources 
Claustrophobia - Manufacturers - Contrast Agents - Resources - Education pool - Knee MRI
 
Field Even Echo Rephasing
 
The FEER method was the first clinically useful flow quantification method using phase effects, from which all spin phase related flow quantification techniques currently in use are derived.
In this sequence a gradient echo is measured after a gradient with flow compensation. The measured signal phase should be zero for all pixels. A deviation from gradient symmetry by shifting the gradient ramp slightly away from the symmetry condition will impart a defined phase shift to the magnetization vectors associated with spins from pixels with flow.
Slight stable variations in the magnetic field across the imaging volume will prevent the phase angle from being uniformly zero throughout the volume in the flow-compensated image. The first image (acquired without gradient shift) serves as reference, defining the values of all pixel phase angles in the flow (motion) compensated sequence. Ensuing images with gradient phase shifts imparted in each of the 3 spatial axes will then permit measurement of the 3 components of the velocity vector v = (vx, vy, vz) by calculating the respective phases px, py and pz by simply subtracting the pixel phases measured in the compensated image from the 3 images with a well defined velocity sensitization.
The determination of all 3 components of the velocity vector requires the measurement of 4 images.
The phase quantification requires an imaging time four times longer than the simple measurement of a phase image and associated magnitude image. If only one arbitrary flow direction is of interest, it suffices to acquire the reference image plus one image velocity sensitized in the arbitrary direction of interest.

See also Flow Quantification.
spacer
Field Gradient
 
spacer

• View the DATABASE results for 'Field Gradient' (32).Open this link in a new window

 
Further Reading:
  News & More:
Active Noise Control of Magnetic Resonance Imaging Scanner Using Inverse Modeling Technique
Monday, 19 April 2010   by www.acoustics.org    
Field Homogeneity
 
The field homogeneity is a very important factor for image quality. The field should be homogenous in the range of 1-10ppm over 30-50cm for high-quality imaging.
spacer

• View the DATABASE results for 'Field Homogeneity' (11).Open this link in a new window

 
Further Reading:
  Basics:
MRI Quality Control Program
   by www.simplyphysics.com    
  News & More:
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
Abdominal MRI at 3.0 T: The Basics Revisited
Wednesday, 20 July 2005   by www.ajronline.org    
Optimizing SPIR and SPAIR fat suppression
Tuesday, 30 November 2004   by clinical.netforum.healthcare.philips.com    
MRI Resources 
MR Guided Interventions - Mobile MRI - Education pool - Spectroscopy pool - Research Labs - Software
 
previous       46 - 50 (of 98)      next 
Fa-Fa   Fa-Fa   Fa-Fa   Fa-Fa   Fa-Fe   Fe-Fe   Fe-Fe   Fe-Fe   Fe-Fi    Fi-Fi    Fi-Fi   Fi-Fl   FL-Fl   Fl-Fl   Fl-Fl   Fo-Fo   FO-Fr   Fr-Fr   Fr-Fu   Fu-Fu   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]