| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | | | | |
| | |
|
| |
| | | | | | | | | | • View the NEWS results for 'Heart MRI' (18).
| | | | Further Reading: | | Basics:
|
|
News & More:
| |
| | | |
|
| |
| The element helium (He) was discovered 1868 when P.J.C. Janssen and N. Lockyer detected a new line in the solar spectrum during the solar eclipse. Lockyer and E. Frankland suggested the name helium (Gr. Helios, the sun) for the new element. In 1895, helium was discovered in the uranium mineral cleveite and in 1907 it was found out that alpha particles are helium nuclei.
Properties: Helium belongs to the noble gases, is colorless, odorless, and occurs in two naturally isotopes, helium 3 and helium 4. As an inert gas, helium does not react chemically largely and don't burns. Helium 4 makes up over 99% of naturally occurring helium atoms. Helium is extracted from natural gas e.g. present in various radioactive minerals as a decay product. Deposits and sources are in the USA, Poland, the USSR, and a few in India. The rare deposits and increased consumption lead to a shortage of this gas.
K. Onnes worked for many years to liquefy helium, which persisted as a gas to the lowest temperature. Helium does not freeze at atmospheric pressure.
The density of helium vapor at his boiling point of 4.2 Kelvin is very high, with the vapor expanding greatly when heated to room temperature.
Nb, Tc, Pb, La, V, and Ta are superconductors at liquid helium temperature. Liquid helium is commonly used as a cryogen for superconducting magnets. A rapid evaporation of the cryogen is named Quench. See also Quenching.
Cryogenic liquids and their associated cold vapors can produce effects on the skin similar to a thermal burn and can cause frostbite. Prolonged breathing of extremely cold gases may damage the lungs and in absence of enough air or oxygen, asphyxiation and death can occur. Unprotected skin can stick to very cold metal (e.g. cooled by liquid helium) and then tear when pulled away. | | | | • View the NEWS results for 'Helium' (2).
| | | • View the DATABASE results for 'Helium' (43).
| | | | Further Reading: | Basics:
|
|
News & More:
| |
Renergen surges after xceptional™ helium concentration reports Monday, 29 March 2021 by www.businesslive.co.za | | |
Not just balloons: Helium shortage may deflate MRIs, airbags and research Friday, 3 May 2019 by eu.usatoday.com | | |
Liquid helium, the lifeblood of MRI machines Tuesday, 5 March 2019 by www.gasworld.com | | |
Preclinical Imaging Systems Reduce Environmental Impact Monday, 4 November 2019 by www.itnonline.com | | |
Huge newfound deposit of helium will keep MRI scanners running Monday, 27 June 2016 by www.newscientist.com | | |
Philips launches Ingenia Ambition X 1.5T MR with industry-first fully sealed magnet for more productive, helium-free operations Tuesday, 11 September 2018 by www.philips.com | | |
Tech firms, medical research threatened by helium shortage Thursday, 19 September 2013 by www.livemint.com | | |
How 9/11 Made The Global Helium Shortage Worse Thursday, 3 July 2014 by www.popsci.com | | |
Cooling MRI magnets without a continuous supply of scarce helium Tuesday, 13 August 2013 by www.wired.co.uk |
|
| | | | | | |
|
| |
| Pair of current carrying coils used to create uniform magnetic field in the center of the space between them. For circular coils, their separation equals their radius. | | | | | Further Reading: | Basics:
|
|
News & More:
| |
| | | |
|
| |
| A Helmholtz pair consists of two identical circular magnetic coils that are placed symmetrically one on each side of the experimental area along a common axis, and separated by a distance equal to the radius of the coil. Actually, a slightly larger separation improves the field uniformity. Each coil carries an equal electrical current flowing in the same direction. A cylindrical region extending between the centers of the two coils and approximately 1/5 of their diameter will have a nearly spatially uniform magnetic field.
In MRI, the Helmholtz pair coils are used as z- gradient coils to produce linear variations in the main magnetic field along the z-axis. Also in use as z- gradient coils are the Maxwell coils (three coils in a slightly more complicated geometry than the Helmholtz configuration). These coils are only occasionally used as RF coils for imaging. | | | | • View the DATABASE results for 'Helmholtz Pair Coil' (2).
| | | | Further Reading: | Basics:
|
|
News & More:
| |
| | | |
|
| |
| | | | | • View the DATABASE results for 'Hepatobiliary Chelates' (6).
| | | | | | | | | |
| | |
|
| |
| Look Ups |
| |