Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 MRI Database 
SEARCH FOR    
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
previous     11 - 15 (of 167)     next 
S--Sa   Sa-Sc   Sc-Se     Se-Se   Se-Se   Se-Se   Sh-Sh   Sh-SH   Sh-Sh   SH-Si   Si-Si   Si-Si   Si-Si   Si-Si   Si-Si   Sk-Sl   Sl-Sl   Sl-So   So-Sp   Sp-Sp   Sp-Sp   Sp-Sp   SP-Sp   Sp-Sp   Sp-Sp   Sp-Sp   Sp-St   St-St   St-St   St-Su   Su-Su   Su-Sw   Sy-Sy   Sy-Sy   
MRI Resources 
IR - Raman Spectroscopy - Guidance - MRCP - MRI Reimbursement - Lung Imaging
 
Scan Percentage
 
This sequence parameter affects the image resolution and the SNR. By reducing the scan percentage, the resolution decreases and the signal increases.
spacer
Scan TimeForum -
there are related threads
 
(SCT) The total scan time is the time required to collect all data needed to generate the programmed images. The scan time is related to the used pulse sequence and dependent on the assemble of parameters like e.g., repetition time (TR), Matrix, number of signal averages (NSA), TSE- or EPI factor and flip angle.
For example, the total scan time for a standard spin echo or gradient echo sequence is number of repetitions x the scan time per repetition (means the product of repetition time (TR), number of phase encoding steps, and NSA).

See also Number of Excitations, Turbo Spin Echo Turbo Factor, Echo Planar Imaging Factor, Flip Angle and Image Acquisition Time.

See also acronyms for 'scan time parameters' from different manufacturers.
spacer

• View the NEWS results for 'Scan Time' (10).Open this link in a new window.

• View the DATABASE results for 'Scan Time' (47).Open this link in a new window

 
Further Reading:
  Basics:
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
  News & More:
For MRI, time is of the essence A new generation of contrast agents could make for faster and more accurate imaging
Tuesday, 28 June 2011   by scienceline.org    
Clinical evaluation of a speed optimized T2 weighted fast spin echo sequence at 3.0 T using variable flip angle refocusing, half-Fourier acquisition and parallel imaging
Wednesday, 25 October 2006
MRI Resources 
Directories - Manufacturers - NMR - Knee MRI - Resources - Implant and Prosthesis pool
 
Schering AlmanMRI Resource Directory:
 - Manufacturers -
 
[This entry is marked for removal.]

Schering Alman, was a subsidiary of Schering AG, a local distributor of contrast media and pharmaceutical's in Turkey.
In June 2006 Bayer AG has bought the majority of shares of Schering AG. As a result of this take-over Schering AG has been renamed in December 2006 in Bayer Schering Pharma AG.
Contact Information
MAIL
Bayer Türk Kimya San. Ltd. Þti.
Çakmak Mah. Balkan Cad. No:53
34770 Ümraniye / Ýstanbul
PHONE
(0 216) 528 36 00
FAX
(0 216) 527 87 00
spacer
SecondForum -
there are related threads
 
The second is the SI unit of time.
Definition: The length of time taken for 9192631770 periods of vibration of the caesium-133 atom to occur.
spacer

• View the NEWS results for 'Second' (31).Open this link in a new window.

• View the DATABASE results for 'Second' (79).Open this link in a new window

Segmented HASTE
 
A variation of the (Half Fourier Acquisition Single Shot Turbo Spin Echo) HASTE sequence, whereat half of the image information is acquired after the first excitation pulse, and the half after the second excitation pulse. The acquired data are then interleaved into the raw data matrix. A long time to repetition (TR) is selected to allow the spin system to recover between excitation pulses and the dead time is used for additional slices. The length of the echo train is cut in half. Also more than 2 segments are possible.
spacer

• View the DATABASE results for 'Segmented HASTE' (2).Open this link in a new window

MRI Resources 
Spectroscopy - General - Jobs pool - Musculoskeletal and Joint MRI - Mass Spectrometry - Anatomy
 
previous       11 - 15 (of 167)      next 
S--Sa   Sa-Sc    Sc-Se    Se-Se   Se-Se   Se-Se   Sh-Sh   Sh-SH   Sh-Sh   SH-Si   Si-Si   Si-Si   Si-Si   Si-Si   Si-Si   Sk-Sl   Sl-Sl   Sl-So   So-Sp   Sp-Sp   Sp-Sp   Sp-Sp   SP-Sp   Sp-Sp   Sp-Sp   Sp-Sp   Sp-St   St-St   St-St   St-Su   Su-Su   Su-Sw   Sy-Sy   Sy-Sy   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]